Research Article

Determination of Modelling Error Statistics for Cold-Formed Steel Columns

Table 1

Dimension measurement details of two number of CFS lipped channel specimens.

SpecimenSection NoDistanceWeb (mm)Flange1 (mm)Flange2 (mm)Lip1 (mm)Lip2 (mm)Thk1 (mm)Thk2 (mm)

110.0090.4250.0049.7919.9020.503.253.25
20.5089.7750.0350.0320.2420.45
31.0090.2650.3650.2919.6820.43
41.5089.7550.4450.4719.5819.55
52.0089.9149.9650.4019.6019.86
62.5089.9450.2950.3419.5219.55
73.0090.4749.6550.5020.0920.243.253.40
Average90.0750.1050.2619.8020.083.253.33

210.0089.5250.4449.7020.0519.543.223.20
20.5090.4650.4649.8020.0519.60
31.0090.2650.3050.4420.2519.80
41.5090.3950.1849.9320.2219.94
52.0089.5249.8150.0319.7719.81
62.5089.6449.8949.5819.7020.44
73.0090.0449.5549.9319.8619.563.173.60
Average89.9850.0949.9219.9819.813.203.40

Minimum dimension required90.0050.0050.0020.0020.003.153.15