Roof subsidence with different bolt diameters.

Dynamic time (s)Roof subsidence (mm)
φ = 16 mmφ = 18 mmφ = 20 mmφ = 22 mm

T = 0.00 s56.1056.9056.3455.87
T = 0.02 s56.1056.9956.3455.89
T = 0.04 s69.6668.8767.8167.32
T = 0.06 s78.0877.8877.2277.00
T = 0.08 s111.80110.05110.70110.44