Seismic Response and Vibration Reduction Analysis of Suspended Structure under Wave Passage Excitation

Table 7

Peak strain response of key parts.

CaseLocationModelConcrete strain (με)
Uniform800 m/s500 m/s300 m/s

El Centro waveBCCommon154152−1.3%17211.7%150−2.6%
Damping70722.9%62−11.4%63−10%
EBCommon19229051.0%27442.7%1993.7%
Damping689336.8%680702.9%
MBCommon6056−6.7%52−13.3%4328.3%
Damping313616.1%30−3.2%336.5%

Taft waveBCCommon16118414.3%1673.7%154−4.4%
Damping7843−44.9%76−2.6%791.3%
EBCommon19428546.9%25531.4%22415.5%
Damping536726.4%6318.9%541.9%
MBCommon52555.8%5811.5%5811.5%
Damping303310%29−3.3%300

Artificial waveBCCommon16631891.6%30382.5%20020.5%
Damping8780−8.1%81−6.9%83−4.6%
EBCommon17623433.0%20214.8%19410.2%
Damping95878.4%83−12.6%83−12.6%
MBCommon49538.2%6226.5%6940.8%
Damping26273.9%287.7%24−7.7%

Note 1: the “BC” indicates the bottom of the column, the “EB” indicates the ends of the hanging beam, and the “MB” indicates the midspan of the hanging beam. Note 2: a negative in the above table indicates that the value is a negative increase, i.e., the actual value is reduced.