Research Article

Failure Mechanism and Mitigation Measures of the G1002 Electricity Pylon Landslide at the Jinping I Hydropower Station

Figure 13

Anchor cables with lattice frame beams to control the residual masses (2-2′ cross section). The 30 m and 22 m anchor cables with 8 m anchorage length are alternatingly installed. Each anchor cable consists of 7 steel strands with high strength and low relaxation. The design load of the anchor cables is 1000 kN/m, and the working load can reach 700 kN/m.