Research Article
Shear Strength of Internal Reinforced Concrete Beam-Column Joints: Intelligent Modeling Approach and Sensitivity Analysis
Table 2
Statistics of parameters for the internal RC beam-column joints.
| Parameter | Unit | Maximum | Minimum | Mean | St.D. | Type |
| f c | MPa | 116.90 | 16.57 | 43.31 | 19.07 | Input | b c | mm | 458.00 | 200.00 | 268.12 | 66.03 | Input | h c | mm | 458.00 | 200.00 | 277.23 | 81.72 | Input | b b | mm | 406.00 | 150.00 | 194.74 | 64.60 | Input | h b | mm | 500.00 | 250.00 | 322.59 | 56.96 | Input | f y,b | MPa | 1456.00 | 314.00 | 457.48 | 179.87 | Input | f y,c | MPa | 1456.00 | 314.00 | 458.09 | 150.46 | Input | | MPa | 1374.00 | 276.00 | 451.73 | 262.08 | Input | | % | 2.00 | 0.18 | 0.66 | 0.38 | Input | n | — | 1.18 | 0.00 | 0.25 | 0.23 | Input | τ | MPa | 14.87 | 2.85 | 7.30 | 2.81 | Output |
|
|