DA300 lux distribution of fully glazed open office in cardinal orientations (Algiers).

Reference modelSTPV 30%
South = 97%East = 95%North = 92%West = 94%South = 16%East = 11%North = 0%West = 8%

STPV 20%STPV 10%
South = 3%East = 1%North = 0%West = 2%South = 0%East = 0%North = 0%West = 0%

STPV 10% 50%STPV 10% 75%
South = 66%East = 41%North = 3%West = 36%South = 24%East = 17%North = 0%West = 12%

STPV 20% 50%STPV20% 75%
South = 68%East = 43%North = 4%West = 37%South = 31%East = 20%North = 0%West = 16%

STPV 30% 50%STPV 30% 75%
South = 73%East = 45%North = 6%West = 40%South = 40%East = 26%North = 0%West = 21%