Research Article
Study on Stressing State and Failure Criterion of Concrete-Filled Stainless Steel and Steel Tubular Column
Table 3
Comparison of experimental data and simulated data.
| Specimen number | Failure load of experiment (kN) | Simulated ultimate load (kN) | Error (%) | Failure load of experiment (kN) | Simulated failure load (kN) | Error (%) |
| Z-48-a | 698 | 670 | 4.0 | 613 | 610 | −0.6 | Z-48-b | 660 | 670 | 1.5 | 609 | 610 | 0.1 | Z-48-a | 618 | 567 | 8.3 | 535 | 521 | −2.8 | Z-76-b | 578 | 567 | 1.9 | 540 | 521 | −3.6 | Z-89-a | 493 | 494 | 0.2 | 462 | 459 | −0.7 | Z-89-b | 520 | 494 | 5.0 | 468 | 459 | −2.0 |
|
|