Research Article
Research on the Deformation and Control Technology of Surrounding Rock in Entry Retaining along the Gob Side
Table 2
Roadway support parameters.
| The name of roadway | E1316 intake entry |
| The gross section | Digging width (mm) | 5900 | Digging height (mm) | 4050 | Excavating area (m2) | 23.90 | The net section | Net width (mm) | 4000 | Net height (mm) | 3850 | Net area (m2) | 15.40 | The row and line space between roof bolts (mm) | 800 × 900 | The row and line space between floor bolts (mm) | 900 × 900 | Layout of roof anchor cable | Four or four layouts | The row and line space between anchor cables (mm) | 1400 × 900 | Layout of floor anchor cable | Two or two layout | The row and line space between anchor cables (mm) | 1400 × 1800 | Layout of ladder beam | Side (single reinforcement) | Ф14 × 3700 | Roof (double reinforcement) | Ф14 × 5000 | | Layout of mesh (mm) | Side | 4200 × 950 | Roof | 5300 × 950 |
|
|