Experimental Study on SSRC under Eccentric Compression
Table 4
Main test data.
Specimen number
(kN)
(10−6)
(10−6)
Failure pattern
A-D1
0.913
242.2
−1195.05
6152.23
Large eccentricity
A-D4
0.228
807.2
−2422.90
384.45
Small eccentricity
B-D1
0.922
302.1
−1251.09
4183.15
Large eccentricity
B-D2
0.691
440.5
−1850.98
2983.35
Large eccentricity
B-D3
0.461
625.4
−2657.56
1707.61
Small eccentricity
B-D4
0.230
952.0
−2775.89
279.73
Small eccentricity
C-D1
0.941
353.5
−1166.36
1724.76
Large eccentricity
C-D4
0.235
1032.0
−1877.59
−16.99
Small eccentricity
Note: represents the maximum bearing load of the specimen, and and represent the strain of compression stainless steel and tension stainless steel bars, respectively, when the threshold load is reached. In this table, negative values represent compression and positive values represent tension.