Research Article
Limit Analysis of Collapse Mechanisms for Tunnel Roofs Subjected to Pore Water Pressure: A Numerical Approach
Table 3
Comparison of height H and width L of collapse block between theoretical solutions and numerical solutions with varied parameter σt/σc.
| Variable | Theoretical solutions | Numerical solutions | Differences | σt/σc | Ht (m) | Lt (m) | Hn (m) | Ln (m) | ΔH = Ht − Hn (m) | ΔL = Lt − Ln (m) | ΔH/Ht (%) | ΔL/Lt (%) |
| 1/50 | 19.4286 | 32.0949 | 19.4247 | 32.0949 | 0.0039 | 0.0000 | 0.0201 | 0.0000 | 1/75 | 12.9524 | 24.1641 | 12.9502 | 24.1643 | 0.0022 | −0.0002 | 0.0170 | −0.0008 | 1/100 | 9.7143 | 19.7567 | 9.7129 | 19.7568 | 0.0014 | −0.0001 | 0.0144 | −0.0005 | 1/200 | 4.8571 | 12.1617 | 4.8566 | 12.1617 | 0.0005 | 0.0000 | 0.0103 | 0.0000 | 1/300 | 3.2381 | 9.1565 | 3.2378 | 9.1565 | 0.0003 | 0.0000 | 0.0093 | 0.0000 |
|
|
Note: the parameters in the calculation are A = 2/3, B = 0.7, σc = 1 × 104 kPa, γ = 25.0 kN/m3.
|