Research Article

Optimization of Daylighting, Ventilation, and Cooling Load Performance of Apartment in Tropical Ocean Area Based on Parametric Design

Table 3

Zone energy parameter.

MemberParameterValue

EP zone loadsEquipment load (W/m2)14
Light density (W/m2)5
Number of people (ppl/m2)0.04
EP zone thresholdsCooling set point (°C)26
HVAC systemPTAC