Research Article

A Robust Estimate Method for Damage Detection of Concrete Structures Using Contaminated Data

Table 1

The error degrees of damage assessment by different methods.

CaseLocation of damageSVT (%)First AIE (%)Second AIE (%)Third AIE (%)Fourth AIE (%)

1Element 1528.639.30.80.80.8
2Elements 6 and 1826.328.91.00.80.6
3Element 2183.97.85.10.80.8