Research Article
Model Testing of Encased Stone Column Composite Foundations under Traffic Loads
Table 4
Plate loading tests on the composite foundations.
| Test type | Experimental label | Encased length of column (mm) | Cyclic load ratio | Total number of the test |
| Single column | A1 | 400 | 0.2 | 2 | B1 | 400 | 0.3 | 2 | C1 | 400 | 0.4 | 2 | D1 | 400 | 0.5 | 2 |
| Composite foundation with a column | A2 | 400 | 0.2 | 2 | B2 | 400 | 0.3 | 2 | C2 | 400 | 0.4 | 2 | D2 | 400 | 0.5 | 2 |
|
|