Research Article

Experimental Investigation on the Load-Carrying Capacity of Steel-to-Laminated Bamboo Dowel Connection I: Single Fastener with Slotted-In Steel Plate under Tension

Table 2

The test results of the connections in different groups.

No.γFy (kN)Δy (mm)K1(kN/mm)Fu (kN)Δu (mm)K2 (kN/mm)

T1-D1-L14.5032.331.1743.5650.5612.054.7710.30
T2-D1-L11.1723.401.2628.7827.152.492.651.98
T3-D1-L12.4225.661.4034.4538.336.963.424.97
T4-D1-L13.6730.151.4438.7645.4812.465.168.65
T1-D2-L15.4028.891.9829.5645.0819.003.959.60
T1-D3-L13.8639.561.8644.4262.4916.902.809.09
T1-D4-L13.3848.562.5453.2872.9818.983.097.47
T1-D1-L24.5030.261.3638.1444.455.033.213.70
T1-D1-L34.5032.161.2645.5650.8313.324.8110.57
T1-D1-L44.5033.881.3944.2852.8216.535.2311.89