Research Article

Experimental Investigation on Atomization and Dustfall Characteristics of Combined Nozzles for Shearer External Spray in Fully Mechanized Coal Mining Face

Table 5

Average dust concentration at different measuring points at the coal dust source.

Measurement pointNondust-proof measuresOpen traditional sprayOpening a new type of external spray unit (distance between nozzles)/mm
150200250
Total dust concentration (mg/m3)Respirable dust concentration (mg/m3)Total dust concentration (mg/m3)Respirable dust concentration (mg/m3)Total dust concentration (mg/m3)Respirable dust concentration (mg/m3)Total dust concentration (mg/m3)Respirable dust concentration (mg/m3)Total dust concentration (mg/m3)Respirable dust concentration (mg/m3)

1#774.0376.1305.2143.7227.5115.4148.570.3179.284.9
2#993.4482.8382.9186.4278.3136.7171.680.2194.597.3
3#435.6221.9223.6104.1140.767.195.240.7109.447.8
4#262.1118.7132.764.782.241.560.424.068.930.6
5#217.5103.494.346.564.830.247.322.152.025.7