Research Article
Internet of Things-Based Concrete Curing Invention for Construction Quality Control
Table 6
Record of concrete surface temperature and dampness in Experiment B.
| Sample/time | Surface temperature | Surface dampness | (1) Air-based curing (°C) | (2) IoT-based curing (°C) | (3) Manual-based curing (°C) | (1) Air-based curing (%) | (2) IoT-based curing (%) | (3) Manual-based curing (%) |
| 5 minutes | 20.0 | 20.0 | 23.9 | 11.6 | 47.5 | 44.1 | 10 minutes | 20.0 | 20.0 | 23.2 | 11.6 | 42.3 | 37.6 | 15 minutes | 20.0 | 20.0 | 23.4 | 10.3 | 46.8 | 33.6 | 20 minutes | 20.1 | 20.0 | 23.2 | 11.5 | 42.7 | 35.4 | 25 minutes | 20.1 | 20.1 | 23.2 | 11.5 | 44.8 | 33.0 | 30 minutes | 20.2 | 20.2 | 23.1 | 10.9 | 40.9 | 32.9 | 35 minutes | 20.1 | 20.1 | 22.5 | 10.5 | 47.6 | 46.6 | 40 minutes | 20.0 | 20.0 | 23.1 | 11.7 | 44.1 | 38.4 | 45 minutes | 20.3 | 20.0 | 22.7 | 9.6 | 43.8 | 35.2 | 50 minutes | 20.1 | 20.1 | 22.4 | 11.8 | 43.3 | 35.8 | 55 minutes | 20.0 | 20.0 | 22.3 | 11.5 | 43.3 | 31.6 | 60 minutes | 20.5 | 19.9 | 22.3 | 11.4 | 45.2 | 45.1 | 65 minutes | 20.5 | 20.0 | 22.1 | 11.5 | 47.6 | 41.2 | 70 minutes | 20.5 | 20.3 | 22.0 | 11.4 | 42.5 | 33.3 | 75 minutes | 20.5 | 19.7 | 22.0 | 11.2 | 44.3 | 46.2 | 80 minutes | 20.5 | 20.4 | 21.9 | 11.3 | 42.1 | 36.1 | 85 minutes | 20.0 | 20.3 | 21.1 | 13.5 | 45.2 | 32.2 | 90 minutes | 20.4 | 20.0 | 21.0 | 7.9 | 40.0 | 35.4 | 95 minutes | 20.4 | 20.3 | 21.0 | 9.2 | 44.0 | 38.7 | 100 minutes | 20.1 | 20.2 | 21.0 | 11.4 | 38.5 | 37.6 | 105 minutes | 20.9 | 20.2 | 21.0 | 11.6 | 40.0 | 33.2 | 110 minutes | 20.5 | 21.0 | 21.0 | 10.6 | 40.3 | 35.9 | 115 minutes | 21.0 | 20.3 | 21.0 | 11.6 | 43.2 | 36.9 | 120 minutes | 20.9 | 20.4 | 21.0 | 11.7 | 41.4 | 34.1 |
|
|