Model details used in the study performance analysis.

ReferenceModelSize of unit in “m”Areas in SqmWall thickness in “m”The material used for the studyCode of reference

S.P. Raut et al. [26]Single room1 × 110.11Papermill waste (PMW)SP-7-2016 (National Building Code—NBC)
M.V. Madurwar et al. [27]Single room1 × 110.13Sugar cane bagasse ash (SCBA)
R. Chippagiri et al. [21]Single room3 × 390.1Co-fired blended ash (CBA)
R. Ralegaonkar et al. [28, 29]1 BHK –GFTypical270.15 Ext.Bio-fuel ash (BFA)
0.10 Int.
H. Gavali et al. [30, 31]1BHK –GFTypical27.50.15 Ext.Co-fired blended ash (CBA)
0.11 Int.