Research Article

Preliminary Results of Shake Table Tests of a Typical Museum Display Case Containing an Art Object

Figure 5

Spectrum-compatibility analysis: required response spectra (RRS) and test response spectra (TRS) along the X direction. The results are related to tests: (a) AC02 (SDS equal to 0.10 g), (b) AC05 (SDS equal to 0.25 g), and (c) AC09 (SDS equal to 0.45 g). “TRS X - Test” and TRS X - Input” spectra correspond to recorded test signal and assigned input signal.
(a)
(b)
(c)