Research Article
Study on the Relation between Tailing Particle Size and Tailing Slurry Underflow Concentration
Table 5
The relation between particle size and underflow concentration.
| The relation between median particle size of tailings d50 and underflow concentration of static settlement test C1 | |
| The relation between underflow concentration of static settlement test C1 and underflow concentration of dynamic thickening test C2 | Overflow solid content | C2 = -0.0162 C12 + 2.8395 C1- 38.987 | At 200 ppm | Overflow solid content | C2 = −0.0153 C12 + 2.7288 C1 − 36.067 | At 240 ppm | Overflow solid content | C2 = −0.0162 C12 + 2.8395 C1 − 38.987 | At 270 ppm | Overflow solid content | C2 = −0.0145 C12 + C1 − 32.778 | At 300 ppm |
|
|