Research Article

Hydraulic Simulation of Leakage in Post-Earthquake Water Supply Pipeline Network and Its Algorithm Improvement

Table 3

Evaluation results of water supply rate of water supply network using different pipes.

IntensityLiquefactionMaterialSamples number mean standard deviationRisk value

VIINoCast iron pipe66280.9850.0590.015
VIIINoCast iron pipe55480.9610.1110.039
IXintermediateCast iron pipe55970.8060.0940.194
XSeverityCast iron pipe64830.2960.0860.704
IXintermediateSteel pipe53140.9070.0920.093