Research Article
Performance Investigation of a Silicon Photovoltaic Module under the Influence of a Magnetic Field
Table 2
Values of current and voltage of the photovoltaic module against the intensity of the magnetic field and for a solar irradiance of 600 W/m2.
| | B (mT) | | 0 | 15 | 30 | 50 | Temperature at front side | Temperature at back side | Ambient temperature | (V) | (mA) | (mA) | (mA) | (mA) | T1 (°C) | T2 (°C) | T3 (°C) |
| 0 | 205 | 176.12 | 137 | 90.4 | 38.9 | 37.7 | 52.6 | 2 | 201 | 174.49 | 136.2 | 90.16 | 43.9 | 41.3 | 54.5 | 4 | 198.35 | 172.38 | 135 | 89.7 | 43.7 | 41.5 | 53.5 | 6 | 193.25 | 170.79 | 132.85 | 87.8 | 42 | 41.6 | 54.7 | 8 | 187 | 168 | 130 | 85.2 | 43 | 41.4 | 54.6 | 10 | 176.42 | 160.65 | 127.75 | 82.9 | 43.6 | 41.2 | 53.6 | 12 | 164.69 | 150.62 | 123 | 79.7 | 44.2 | 41 | 52.8 | 14 | 148.03 | 134.79 | 117 | 77 | 44.3 | 41.2 | 52.9 | 16 | 120.29 | 113 | 102 | 71.88 | 44 | 41.3 | 52.8 | 18 | 57 | 65.05 | 66.67 | 63.44 | 43.4 | 41 | 52.7 | 18.45 | 42.96 | 52 | 55.83 | 59 | 43.8 | 41.4 | 54 | 18.94 | 27 | 37 | 44.88 | 51 | 43.8 | 41 | 55.5 | 20 | 0 | 7 | 14 | 24.2 | 41.6 | 40.3 | 54.4 | 20.91 | 0 | 0 | 0 | 2 | 41.4 | 40.8 | 55 | 21.5 | 0 | 0 | 0 | 0 | 42.1 | 41.4 | 54.6 |
|
|