Research Article

Performance Investigation of a Silicon Photovoltaic Module under the Influence of a Magnetic Field

Table 3

Electric power and voltage of the photovoltaic module against the intensity of the magnetic field for a solar irradiance of 600 W/m2.

B (mT)
0153050Temperature at front sideTemperature at back sideAmbient temperature
(V)(W) (W) (W) (W)T1 (°C)T2 (°C)T3 (°C)

0000038.937.752.6
20.4020.3490.2720.1843.941.354.5
40.7930.670.540.35943.741.553.5
61.161.0250.7970.5274241.654.7
81.4961.3441.040.6824341.454.6
101.7641.6071.2780.82943.641.253.6
121.9761.8071.4760.95644.24152.8
142.0721.8871.6381.07844.341.252.9
161.9251.8021.6321.1524441.352.8
181.0261.1711.21.14243.44152.7
18.450.7930.961.031.08943.841.454
18.940.5110.7010.850.96643.84155.5
2000.140.280.04841.640.354.4
20.910000.04241.440.855
21.5000042.141.454.6