Research Article
Performance Investigation of a Silicon Photovoltaic Module under the Influence of a Magnetic Field
Table 3
Electric power and voltage of the photovoltaic module against the intensity of the magnetic field for a solar irradiance of 600 W/m2.
| | B (mT) | | 0 | 15 | 30 | 50 | Temperature at front side | Temperature at back side | Ambient temperature | (V) | (W) | (W) | (W) | (W) | T1 (°C) | T2 (°C) | T3 (°C) |
| 0 | 0 | 0 | 0 | 0 | 38.9 | 37.7 | 52.6 | 2 | 0.402 | 0.349 | 0.272 | 0.18 | 43.9 | 41.3 | 54.5 | 4 | 0.793 | 0.67 | 0.54 | 0.359 | 43.7 | 41.5 | 53.5 | 6 | 1.16 | 1.025 | 0.797 | 0.527 | 42 | 41.6 | 54.7 | 8 | 1.496 | 1.344 | 1.04 | 0.682 | 43 | 41.4 | 54.6 | 10 | 1.764 | 1.607 | 1.278 | 0.829 | 43.6 | 41.2 | 53.6 | 12 | 1.976 | 1.807 | 1.476 | 0.956 | 44.2 | 41 | 52.8 | 14 | 2.072 | 1.887 | 1.638 | 1.078 | 44.3 | 41.2 | 52.9 | 16 | 1.925 | 1.802 | 1.632 | 1.152 | 44 | 41.3 | 52.8 | 18 | 1.026 | 1.171 | 1.2 | 1.142 | 43.4 | 41 | 52.7 | 18.45 | 0.793 | 0.96 | 1.03 | 1.089 | 43.8 | 41.4 | 54 | 18.94 | 0.511 | 0.701 | 0.85 | 0.966 | 43.8 | 41 | 55.5 | 20 | 0 | 0.14 | 0.28 | 0.048 | 41.6 | 40.3 | 54.4 | 20.91 | 0 | 0 | 0 | 0.042 | 41.4 | 40.8 | 55 | 21.5 | 0 | 0 | 0 | 0 | 42.1 | 41.4 | 54.6 |
|
|