Analytical Cellular Pathology

Analytical Cellular Pathology / 1997 / Article

Open Access

Volume 13 |Article ID 953513 | https://doi.org/10.1155/1997/953513

Robert W. Baker, Gerard Brugal, Dulcie V. Coleman, "Assessing Slide Coverage by Cytoscreeners during the Primary Screening of Cervical Smears, Using the AxioHOME Microscope System", Analytical Cellular Pathology, vol. 13, Article ID 953513, 9 pages, 1997. https://doi.org/10.1155/1997/953513

Assessing Slide Coverage by Cytoscreeners during the Primary Screening of Cervical Smears, Using the AxioHOME Microscope System

Received26 Jun 1996
Revised21 Nov 1996

Abstract

We have used the HOME Microscope system to examine the screening patterns of cytotechnologists who undertake the primary screening of cervical smears, in order to measure accuracy of screening against screening time, slide coverage, and mean screening rate. Twelve cytotechnologists engaged routinely on cervical screening volunteered for this study. They were asked to perform primary screening of 10 test slides under normal laboratory conditions in the normal way. Slide coverage and screening time were recorded on the HOME system. Slide maps were prepared and the results analysed.The exercise demonstrated that all primary screeners fail at some point to scan the whole of the slide during primary screening. The maps produced by the HOME system clearly demonstrated that 5 different types of error can occur that lead to incomplete coverage of the slide. Mean slide coverage was 84%, and some individuals averaged only 66% coverage. The results show that there is a major problem in the education of some individual cytotechnologists in slide coverage. This could be rectified by the incorporation of a HOME system into every training centre, and the establishment of a protocol for assessment of slide coverage in competence examinations. Furthermore, the exercise has shown that even those individuals who normally attain a good standard of slide coverage would be able to improve slide coverage given access to the daily use of a HOME Microscope, or a system with equivalent screening/reviewing functionality.

Copyright © 1997 Hindawi Publishing Corporation. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


More related articles

 PDF Download Citation Citation
 Order printed copiesOrder
Views73
Downloads266
Citations

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.