Research Article
Effects of Landscape Design on Urban Microclimate and Thermal Comfort in Tropical Climate
Table 1
Equipment used for field measurement.
| Variable | Instrument | Accuracy |
| Air temperature/relative humidity | HOBO U12-012 Temp/RH Data Logger | ±0.35°C from 0°C–50°C to a maximum of ±3.5% | Globe temperature | HOBO Thermocouple Data Logger, U12-014 with Type-T Copper-Constantan thermocouple sensors and 40 mm diameter ping pong ball | ±1.5°C | Wind speed | Onset Wind Speed Smart Sensor, S-WSA-M003 | ±1.1 m/s or ±4% of reading, whichever is greater | Short- and long-wave radiation | Kipp & Zonen, CNR 4 with integrated pyranometer, pyrgeometer, Pt-100, and thermistor | Pyranometer: <5% uncertainty (95% confidence level) Pyrgeometer: <10% uncertainty (95% confidence level) Pt-100/thermistor: ±0.7°C |
|
|