Deviation of moment parameters between PMCS and OTT in different rain-rate.

Rain-rate mm/hPMCS-OTTM0M1M2M3M4M5M6

0.630.670.760.780.730.630.52
Bias22.0%20.5%19.8%22.2%29.5%42.7%62.3%
ab_bias37.8%34.1%32.9%35.8%43.9%57.8%78.2%

0.550.680.760.750.690.620.57
Bias2.9%6.0%8.9%13.7%21.8%33.6%49.1%
ab_bias26.7%22.5%22.6%27.1%36.0%49.2%66.8%

0.340.540.690.760.740.710.67
Bias−10.1%−2.9%2.1%8.2%17.5%31.1%49.5%
ab_bias34.0%24.0%20.7%22.4%29.4%41.5%59.0%

0.430.540.670.760.780.750.71
Bias−25.8%−15.9%−5.8%6.7%22.5%41.9%64.3%
ab_bias48.1%34.1%25.1%23.2%31.4%47.0%67.8%

All0.660.810.900.920.910.880.82
Bias−1.7%0.9%4.0%10.5%21.8%38.2%59.1%
ab_bias36.7%28.8%24.7%25.4%32.9%46.8%66.4%