Field Assessment of Neighboring Building and Tree Shading Effects on the 3D Radiant Environment and Human Thermal Comfort in Summer within Urban Settlements in Northeast China
Table 1
Main technical parameters of the instruments.
Location
Parameter
Instrument
Quantity/site
Range
Accuracy
Resolution
SHA_Buil/SHA_Tree/SUN_0
Ta
HoBo U23-002
1
−40∼70°C
±0.21°C
0.02°C
RH
0∼100%
±2.5%
0.03%
WFWZY-1
1
0.05∼30 m/s
±0.05 m/s
0.01 m/s
Ki
TBQ-2
6
0∼2000 W/m2
<5%
1 W/m2
Li
TBL-1
6
0∼2000 W/m2
±2%
1 W/m2
Ts
DS1922L
5 at SHA_Buil and SHA_Tree and 1 at SUN_0
−40∼85°C
±0.5°C
0.5°C
All the instruments complied with the ISO 7726 standard [42].