Research Article

An Accurate Estimation of the Eigenfrequency of an Offshore Wind Turbine Considered as the Stepped Euler-Bernoulli Beam in Three-Spring Flexible Foundation Using the Power Series Method

Table 4

Comparison of case 3 data and results from Arany et al. [7].

OWT nameNatural frequency (Hz) and error (%)
MeasuredCase 3ErrorArany et al. [8]Error

I Lely A20.6340.72715.340.6431.36
II Irene Vorrink0.5460.60310.510.552-0.555−1.10
III Blyth0.4880.470−3.600.4890.12
IV Kentish Flats0.3390.3390.010.3390.01
V Barrow0.3690.361−2.080.367−0.54
VI Thanet0.3700.351−5.190.3823.08
VII Belwind0.3720.3781.340.3802.12
VIII Burbo Bank0.2920.2920.070.2951.05
IX Walney0.3500.330−5.680.349−0.40
X Gunfleet Sands0.3140.302−3.820.3150.31
XI ZJU-P0.2620.2661.45