Research Article

Effect of Induced Charge on the Passivity and Passivity Breakdown of 304LN Stainless Steels

Table 8

EDX data in 0.15N KCl solution.

OCrClFe
W%A%W%A%W%A%W%A%

BWC10.628.3316.6514.420.420.5357.6447.48
BPC10.0930.8718.5415.760.40.563.1950.01