Ultrasonic Flaw Detection for Quality Assessment of Explosively Clad Plates
Figure 9
The experimental correlation (corr) of sizes: reflector diameters (real defects) and equivalent reflector sizes (equivalent defects) ; , , and relating to flat bottom hole, hemispherical bottom hole and side drilled hole, respectively; is the theoretical run; is the programme step (1·10−4) within the range of mm.