Research Article
A Study on Occupancy and Compressive Strength of Concrete with Produced Injection Method
Table 1
Ratios of concrete mixtures.
|
Concrete groups |
Concrete mixed water |
Cement (kg/m3) |
Silica fume (kg/m3) |
Fine aggregate (kg) (0–4 mm) |
Large aggregate (kg) (4–16 mm) |
Total
(kg/m3) | Normal concrete | Injected concrete | For normal concrete | For injected concrete |
| Control-30/70 | 212 | 280 | 400 | — | 520 | 1210 | 2342 | 2410 | 30FS5 | 220 | 280 | 380 | 20 | 520 | 1210 | 2350 | 2410 | 30FS10 | 228 | 280 | 360 | 40 | 520 | 1210 | 2358 | 2410 | 30FS15 | | 280 | 340 | 60 | 520 | 1210 | | 2410 | 30FS20 | | 280 | 320 | 80 | 520 | 1210 | | 2410 |
| Control-35/65 | 220 | 300 | 400 | — | 610 | 1120 | 2350 | 2430 | 35FS5 | 232 | 300 | 380 | 20 | 610 | 1120 | 2362 | 2430 | 35FS10 | 236 | 300 | 360 | 40 | 610 | 1120 | 2366 | 2430 | 35FS15 | | 300 | 340 | 60 | 610 | 1120 | | 2430 | 35FS20 | | 300 | 320 | 80 | 610 | 1120 | | 2430 |
| Control-40/60 | 232 | 320 | 400 | — | 690 | 1040 | 2362 | 2450 | 40FS5 | 240 | 320 | 380 | 20 | 690 | 1040 | 2370 | 2450 | 40FS10 | 248 | 320 | 360 | 40 | 690 | 1040 | 2378 | 2450 | 40FS15 | | 320 | 340 | 60 | 690 | 1040 | | 2450 | 40FS20 | | 320 | 320 | 80 | 690 | 1040 | | 2450 |
|
|