Research Article

Estimation of the Pumping Pressure from Concrete Composition Based on the Identified Tribological Parameters

Table 4

Concretes compositions used in the study of Kaplan [4].

ConcretesW/C  (m3)A/SSp/Sp* (mm)Rheological parametersTribological parametersPumping pressures
Slump
(cm)

(Pa)

(Pa)

(Pa·s/m)

(Pa)

(Pa·s/m)

(Pa)

(Pa·s/m)

(bar)

(bar)

(bar)

C=/52/FL0.480.3181.0602.241612218087311147060.9487.725.025.222.9
C=/38/FL0.530.3380.5802.57161221722318534460.9315.918.517.316.0
C=/66/FL0.510.3331.8001.941810771017717935754.4399.818.716.319.0
C−/52/FL0.570.3111.1701.87181077473736426754.4281.014.216.714.3
C−/38/FL0.610.3280.6002.37181077440505625254.4196.013.216.010.9
C−/66/FL0.610.3241.8201.6920932743595324448.0230.812.714.111.9
C=/52/TP0.570.2921.0802.22141365008128867.4347.00.00.00.0
C=/38/TP0.640.3150.5702.24131437775517529070.7238.615.814.213.5
C+/52/TP0.500.3131.0402.1812150913149415045573.9551.926.630.126.2
C+/38/TP0.520.3180.6002.62151293554508133864.2343.818.022.717.3
C+/66/TP0.490.3081.9601.63131437976908934970.7651.918.921.122.9
C−/52/TP0.690.2791.0701.98151293696825820764.2204.711.512.411.8
C−/38/TP0.760.3040.6002.221314375567817020670.7161.617.810.010.4
C+/52/FL0.340.2971.080.81.942186037835126058733.5939.537.835.738.9
C+/38/FL0.400.3230.570.82.45218604031325047033.5474.021.525.020.8
C+/66/FL0.380.3171.880.81.522278837712110466430.3870.932.028.935.6
_0,5%0.410.3301.010.22.1216122111738810062258.1719.825.628.826.9
_1%0.360.3051.090.41.90191005120050071845.6920.124.125.727.0
_1,5%0.370.3111.080.61.88218606551755077836.3748.728.421.426.8
_2%0.350.3011.070.81.87209329002703292636.8883.232.540.131.3