Research Article
Research on Static Triaxial Mechanical Properties of New CementSoil Reinforced with Polypropylene Fiber
Table 6
The results of unconfined compressive strength and triaxial compressive strength test.
| | Compressive strength/MPa | Intensity parameter | | kPa | kPa | kPa | c/kPa | (°) | 7 d | 14 d | 28 d | 7 d | 14 d | 28 d | 7 d | 14 d | 28 d | 7 d | 14 d | 28 d | 7 d | 14 d | 28 d |
| A | 3.8 | 5.0 | 5.2 | 4.5 | 5.5 | 5.7 | 4.8 | 5.9 | 6.5 | 650.36 | 780.2 | 810.9 | 43.2 | 44.4 | 45.9 | B | 4.2 | 5.2 | 6.9 | 4.9 | 5.8 | 7.8 | 5.5 | 6.5 | 8.8 | 760.4 | 820.89 | 881.4 | 45.3 | 46.1 | 52.6 | C | 5.0 | 6.9 | 7.4 | 5.7 | 7.4 | 8.9 | 6.4 | 8.4 | 9.7 | 801.5 | 899.4 | 919.6 | 45.4 | 50.5 | 53.8 |
|
|