Research Article
Microstructural Characterization and Wear Properties of Fe-Based Amorphous-Crystalline Coating Deposited by Twin Wire Arc Spraying
Table 1
Wire arc spraying parameters.
| Parameter | Value |
| Spraying voltage (V) | 32 | Spraying current (A) | 150 | Primary air pressure (MPa) | 0.42 | Secondary air pressure (MPa) | 0.28 | Stand off-distance (mm) | 200 | Number of passes | 1 |
|
|