Research Article

Performance Analysis of CFRP Composite Strips Confined RC Columns under Axial Compression

Table 2

Test results of previous studies: stress enhancement ratio.

PaperDiameter of the column, (mm)Height of the column,
(mm)
Compressive stress value of unconfined column
(), N/mm2
Confinement typeType of fibreStress enhancement ratio,
/

Abdollahi et al. [27] 15030041.7Full wrapNormal modulus CFRP3.32
Au and Buyukozturk [28] 15037524.2Full wrapGFRP1.81
Pon et al. [29] 15012009.6Full wrapCFRP3.26
Bisby et al. [30] 15030034.4Full wrapCFRP1.28
Aire et al. [31]15030042Full wrapCFRP and GFRP2.57
Silva [32]15075026.21Full wrapNormal modulus CFRP1.56
Almusallam [33]15030050.80Full wrapNormal modulus CFRP2.10
Silva and Rodriguez [34] 25075031.2Full wrapCFRP3.03
Benzaid et al. [35] 16032049.5Full wrapNormal modulus CFRP2.55
Smith et al. [36] 25050035Full wrapCFRP1.69
Erdil et al. [37] 15030020.8Full wrapCFRP2.96
Akogbe et al. [38] 30060026.5Full wrapCFRP3.19
Miyauchi et al. [39] 10020031.2Full wrapCFRP3.26
Wang and Wu [40]15030030.9Full wrapCFRP2.41
Hosotani et al. [41] 20060041.72Full wrapCFRP2.23
Shehata et al. [42] 22545034Full wrapCFRP2.41
Santarosa et al. [43] 15030028.1Full wrapCFRP3.05
Thériault et al. [44] 30460837Full wrapCFRP and GFRP3.89
Valdmanis et al. [45] 15030044.3Full wrapCFRP2.60
Wang and Wu [46] 19458251.6Full wrapAFRP3.37
Present study12580020.54Strip wrap (20 mm spacing)Normal modulus CFRP2.99

: stress value of FRP confined column.