Research Article

Optimal Heater Control with Technology of Fault Tolerance for Compensating Thermoforming Preheating System

Table 3

Optimal heater power distribution with the damaged heater.

%12345678

1100.080.788.582.886.388.680.7100.0
249.80.01.90.01.90.00.049.8
38.711.521.539.016.627.811.68.6
470.834.539.4X40.430.134.370.9
530.712.714.849.712.121.913.030.5
630.513.024.62.121.822.412.730.6
770.934.330.135.531.229.834.570.8
88.611.627.823.022.928.011.58.6
949.80.00.00.00.00.00.049.8
10100.080.688.686.386.488.580.7100.0