Research Article
Locally Corroded Stiffener Effect on Shear Buckling Behaviors of Web Panel in the Plate Girder
Table 14
Shear buckling values for the V-L-RL800R800 stiffener series.
|
Corrosion of longitudinal stiffener |
Corrosion of vertical stiffener |
Critical shear buckling load ( | Shear buckling strength ( | With corrosion/without corrosion | End (mm) | Inner (mm) | Height (mm) | Ratio | Load (kN) | Ratio | Load (kN) | Ratio | ratio | ratio |
| 800 (0.8) |
800 (0.8) | 0 | 0 | 460.8 | 1.00 | 755 | 1.00 | 0.85 | 0.93 | 100 | 0.1 | 451.85 | 0.98 | 755 | 1.00 | 0.83 | 0.93 | 200 | 0.2 | 439 | 0.95 | 742.5 | 0.98 | 0.81 | 0.92 | 300 | 0.3 | 422.6 | 0.92 | 707.5 | 0.94 | 0.78 | 0.87 | 400 | 0.4 | 409.55 | 0.89 | 682.5 | 0.90 | 0.75 | 0.84 | 500 | 0.5 | 401.4 | 0.87 | 665 | 0.88 | 0.74 | 0.82 |
|
|