Research Article
Inspection of Wooden Poles in Electrical Power Distribution Networks in Artvin, Turkey
Table 2
Micro Hammer inspection results.
| Location | Number of poles inspected | Velocity (m/s) |
Number of sound poles* |
Number of early stage decayed/damaged poles** |
Number of decayed/damaged poles*** | Average | Std. |
| Area I | 30 | 1710 | 360.7 | 9 | 15 | 6 | Area II | 30 | 2050 | 312.8 | 17 | 10 | 3 | Area III | 30 | 1911 | 264.5 | 13 | 14 | 3 | Area IV | 30 | 2230 | 463.3 | 20 | 8 | 2 |
|
|
Velocity higher than 1500 m/s. Velocity lower than 1500 m/s and higher than 1200 m/s. Velocity lower than 1200 m/s.
|