Research Article
Diffusion Decay Coefficient for Chloride Ions of Concrete Containing Mineral Admixtures
Table 7
Diffusion decay coefficients of concrete by regression analysis.
| W/B (%) | Cement type | Measurement () | Empirical formula () | Error (%) |
| 35 | OPC | 0.34 | 0.34 | | GGBFS20 | 0.36 | 0.38 | | GGBFS40 | 0.43 | 0.42 | | GGBFS60 | 0.45 | 0.47 | | FA10 | 0.63 | 0.66 | | FA20 | 0.96 | 0.87 | | FA30 | 0.99 | 0.99 | |
| 45 | OPC | 0.23 | 0.23 | | GGBFS20 | 0.32 | 0.31 | | GGBFS40 | 0.41 | 0.41 | | GGBFS60 | 0.56 | 0.51 | | FA10 | 0.52 | 0.57 | | FA20 | 0.83 | 0.80 | | FA30 | 0.99 | 0.99 | |
| 55 | OPC | 0.16 | 0.16 | | GGBFS20 | 0.32 | 0.32 | | GGBFS40 | 0.52 | 0.50 | | GGBFS60 | 0.70 | 0.70 | | FA10 | 0.51 | 0.52 | | FA20 | 0.77 | 0.77 | | FA30 | 0.99 | 0.99 | |
|
|