Abstract

The aim of this study was to evaluate the difference in the adsorption behavior of different types of bovine salivary proteins on the PMMA and Ti QCM sensors are fabricated by spin-coating and sputtering onto bare QCM sensors by using QCM and X-ray photoelectron spectroscopy (XPS). SPM, XPS, and contact angle investigations were carried out to determine the chemical composition and surface wettability of the QCM surface. We discuss the quality of each sensor and evaluate the potential of the high-frequency QCM sensors by investigating the binding between the QCM sensor and the proteins albumin and mucin (a salivary-related protein). The SPM image showed a relatively homogeneous surface with nano-order roughness. The XPS survey spectra of the thin films coated on the sensors were similar to the binding energy of the characteristic spectra of PMMA and Ti. Additionally, the amount of salivary-related protein on the PMMA QCM sensor was higher than those on the Ti and Au QCM sensors. The difference of protein adsorption is proposed to be related to the wettability of each material. The PMMA and Ti QCM sensors are useful tools to study the adsorption and desorption of albumin and mucin on denture surfaces.

1. Introduction

The initial adhesion of microorganisms to clinically used dental biomaterials is influenced by physicochemical parameters, such as preadsorption of salivary proteins, and the formation of biofilms begins with the adhesion of microorganisms [1]. The presence of biofilms is thought to affect the ability of microorganisms to adsorb and accumulate on the surfaces of denture materials. Thus, it is likely that bacterial adhesion may also be affected, resulting in a greater risk of infection of the denture materials [2]. Many common materials, such as polymers and metal alloys, are currently used in dentures. Importantly, it is considered that microorganisms are easily adhered to polymer materials; thus, the quantitative investigation of the salivary protein adsorption to denture materials is necessary.

Denture cleanliness is essential to prevent the accumulation of microorganisms owing to its deleterious effects on the mucosa. There are a large number of solutions, pastes, and powders available for cleaning dentures with a variety of claims for their relative efficacies [3]. Chemical solution methods have the advantage of being simple to use. Thus, a quartz crystal microbalance (QCM) sensor device is needed to measure the cleaning ability of the chemical denture cleaner for each denture material.

A QCM is a highly sensitive and practical device for in situ monitoring of protein adsorption [4]. A QCM-based sensor consists of a quartz crystal and a sensing material. A 27 MHz QCM is capable of measuring the mass in aqueous solutions with an extremely high sensitivity, and the resonance frequency has been shown to decrease linearly with increasing mass on the QCM electrode at the nanogram level [5, 6]. QCM sensors have been fabricated by coating a thin film of a biomaterial on the gold electrode of the quartz crystal [710]. Previously, we fabricated poly(methyl methacrylate) (PMMA) and titanium (Ti) QCM sensors by the spin-coating and sputtering methods, respectively, to investigate the adsorption of salivary-related proteins on the denture surface [7, 8, 11]. However, the observation of a thick and nonuniform film on the gold electrode of the quartz crystal was a drawback. Hence, the fabrication of an ultrathin film is necessary for a QCM sensor.

PMMA, Au, and Ti have been used as denture materials owing to their biological safety [1214], and QCM sensor devices that mimic the surface composition of each material will be required. In this study, the spin-coating and sputtering conditions for the fabrication of PMMA and Ti QCM sensors were improved to increase the repeatability and sensitivity. The differences in adsorption behavior of different types of bovine salivary proteins to these sensors were investigated by X-ray photoelectron spectroscopy (XPS).

2. Materials and Methods

2.1. Sample Preparation

To prepare PMMA-coated sensors, the bare QCM sensors were first cleaned with Piranha solution (sulfuric acid: 30% hydrogen peroxide = 7 : 3 v/v). A 0.1 g/mL solution of PMMA in ethyl acetate solution was used to coat the PMMA thin film onto the gold electrode of the quartz crystal at a spinning rate of 3,000 rpm for a period of 15 s in a spin-coater (SC4001, Aiden, Hyogo, Japan). The PMMA QCM sensor was turned on for 24 h at room temperature.

To prepare titanium QCM sensors as target materials, Ti discs with a diameter of 4 inches were used. These thin films were deposited on the gold electrode of the QCM sensors using direct current (DC) for the Ti target magnetron sputtering. The distance between the target and the substrate was 50 mm. The sputtering chamber was evacuated to below 7 × 10−4 Pa using an oil-diffusion pump. The sputtering gas used was Ar gas. The sputtering pressure was maintained at 0.2 Pa for the Ti target using a mass flow controller. The discharge power of the Ti target was 200 W. The target was presputtered for 10 min. The thickness of the Ti layer was 50 nm.

2.2. Characterization of Materials

The surface topology and the roughness of the PMMA, the Ti, and bare QCM sensors were evaluated over a surface area of μm by scanning probe microscopy (SPM-9600, Shimadzu, Kyoto, Japan).

The chemical compositions of the coating on the QCM sensors were analyzed by XPS on an AXIS Ultra DLD spectrometer (Kratos Instruments, Manchester, UK) equipped with a monochromated Al X-ray source ( eV) operated at 75 W. High-resolution spectra were recorded at pass energies of 20 eV. Measurements were performed at a takeoff angle of 90°. All spectra were corrected using the signal of C1s at 285.0 eV as an internal reference. The collected spectra were deconvoluted with a Gaussian-Lorentzian approximation, after Shirley background subtraction, using Vision 2 software (Kratos Instruments).

2.3. Contact Angle Measurements

The contact angle of the QCM sensor surface with respect to double-distilled water was measured using a drop shape analysis system (DSA 10 Mk2; KRÜSS, Hamburg, Germany). The contact angle is a simple measure of the surface energy and the hydrophilic nature of a surface. The mean and standard deviation were calculated for measurements taken at three different locations on each sample.

2.4. Salivary Proteins

Bovine serum albumin (BSA; Wako Pure Chemical Industries Ltd., Osaka, Japan) and bovine submaxillary gland mucin (BSM; Sigma-Aldrich Inc., Tokyo, Japan) were used to mimic human salivary proteins. BSA is a well-characterized protein with a molecular weight of 6.9 × 104, a size of 11.6 × 2.7 × 2.7 nm, and an isoelectric point of 4.7–4.9 [15]. BSM belongs to a glycoprotein class characterized mainly by a molecular weight of 1.6 × 106 and a high level of O-linked oligosaccharides [16]. BSM is the major constituent of mucus in various parts of body and covers the surfaces of the buccal cavity and epithelial organs.

2.5. QCM Measurements

QCM measurements (Affinix QN μ; Initium Co., Ltd., Tokyo, Japan) were used to quantify the amount of adsorbed salivary protein (BSA and BSM). The Affinix QN μ has a 550 μL cell equipped with a 27 MHz QCM plate at the bottom of the cell. The diameter of the quartz plate was 8 mm, and the area of the gold-plated quartz was 4.9 mm2. The unit was equipped with a stirrer bar and a temperature controller. The change in frequency was monitored using a universal frequency counter attached to a microcomputer.

The bare, PMMA, and Ti QCM sensors were immersed in 500 μL PBS solution (0.01 mol/L PBS at pH 7.4). The change in QCM frequency was recorded as a function of time; recording began immediately after the injection of 5 μL (20 μg/mL) of BSA and BSM. The solution was stirred to avoid any protein diffusion effects. This stirring did not affect the stability of the frequency or the magnitude of the change in frequency. The frequency shift depends on the adsorbed mass in accordance with the Sauerbrey equation [17] According to this equation, at 27 MHz, a frequency shift of 1 Hz corresponds to a mass change of approximately 0.62 ng cm−2 (Figure 1). In the Sauerbrey equation, is the measured frequency shift (Hz), is the mass change (g), is the fundamental frequency of the quartz crystal ( Hz), is the electrode area (0.049 cm2), is the density of quartz (2.65 g cm−3), and is the shear modulus of quartz ( dyn cm−2). QCM monitoring was performed at 25°C and the experiment was performed in triplicate. Data are described as the mean ± standard deviation. In this analysis, statistical significance was analyzed using one-way analysis of variance followed by Tukey’s test.

2.6. XPS Analysis after Adsorption Measurement of Bovine Salivary Proteins, BSA and BSM, Using Control, PMMA, and Ti QCM Sensors

The chemical compositions of the adsorbed salivary protein films on the QCM sensors were analyzed by XPS on an AXIS Ultra DLD spectrometer (Kratos Instruments) equipped with a monochromated Al X-ray source ( eV) operated at 75 W. XPS was used to analyze the proteinaceous carbon (C1s) and nitrogen (N1s) signals resulting from the protein. Quantification of the C1s and N1s signals arising from the peptide bonds of the salivary protein was used as a measure of the relative amount of protein adsorbed onto the various surfaces.

3. Results and Discussion

The PMMA QCM sensors were fabricated by spin-coating a thin film of PMMA dissolved in ethyl acetate solution onto Au QCM sensors. Spin-coating from dilute solution is a common method to produce a thin, uniform polymer film on a planar substrate [18]. In general, the fabrication of polymer QCM sensors involves spin-coating the QCM sensors using a dilute solution of polymer. In our previous study, a 1 mg/mL solution of PMMA in chloroform solution was used to coat the PMMA thin film onto the gold electrode of the quartz crystal; however, some aggregation of PMMA was observed on the surface. The Ti thin film was fabricated by a reactive DC magnetron sputtering technique. Magnetron sputtering is one of the most widely used methods, which can be optimized to obtain thin films with desired properties. Magnetron sputtering has become important because it enables control of the structure, composition, and properties of biomaterial thin films through adjustment of the deposition condition [19]. An ultrathin film was required to coat onto the gold electrode of the quartz crystal owing to the improvement of the QCM sensor sensitivity. The 200 nm thick film fabricated in our previous study was improved to 50 nm by changing the discharge power and sputtering time [8].

3.1. SPM Analysis

The surface morphologies of the control, PMMA, and Ti QCM sensors surfaces were investigated over a surface area of μm by SPM. Figure 2 shows the roughness values obtained after SPM image analysis. The surface morphology of the gold-plated quartz is shown in Figure 2(a). The SPM images show the relatively homogenous surface with nano-order grain size. SPM observation clearly revealed the change in surface morphology of the PMMA and Ti QCM sensors, as indicated in Figures 2(b) and 2(c). The surface roughness () values were 1.949, 1.793, and 2.703 nm for the control, PMMA, and Ti QCM sensors, respectively. The size and morphology of the deposited particles were different among the three materials. In this study, ethyl acetate solution was used as a solvent and the rotational speed and PMMA concentration were changed. As a result, the surface roughness () value of the PMMA QCM sensors is smaller than that of our fabricated sensors in our previous study and a uniform surface was obtained [11].

3.2. XPS Analysis

The XPS spectra of the control, PMMA, and Ti QCM sensors are shown in Figures 3, 4, and 5, respectively. The control QCM sensors indicated the presence of Au4f, which is characteristic in atomic Au. The binding energies (BEs) of Au4f7/2 and Au4f5/2 were 84.1 and 87.8 eV, respectively. XPS was performed in this study to determine the chemical composition at the surface of the sample. The Au4f XPS spectrum of the control QCM sensors in this study showed similar BEs of Au4f7/2 (84.0 eV) and Au4f5/2 (87.7 eV), which are characteristic of metallic Au [20, 21].

The C1s spectrum, which is characteristic in atomic carbon (C), and the O1s spectrum, which is characteristic in atomic oxygen (O), were observed for the PMMA QCM sensors. For the PMMA QCM sensor surfaces examined, the C1s envelope was curve-fitted into four components at BEs of 285.0 eV (C-C/C-H), 285.6 eV (C-C-O), 286.7 eV (C-O/C-OH), and 289.0 eV (O=C-O). These results are similar to those previously reported [2126]. For example, Beamson and Briggs’ previous report supports our C1s and O1s XPS spectra of PMMA obtained from the PMMA QCM sensors [26]. The XPS spectra of PMMA thin films coated on the QCM sensors were quite similar to the BE of the characteristic spectra of the PMMA solution. However, it should be noted that surface composition of polymerized PMMA might be changed. Further study of the polymerized PMMA QCM sensor mimicking the denture is needed. The O1s envelope can be fitted with two peaks at 532.1 eV and 533.8 eV, assigned to O=C and O-C, respectively. The Ti2p spectrum was observed from the core-level spectrum of Ti QCM sensors, which is a characteristic of atomic Ti. Furthermore, in the Ti2p spectrum of the Ti surface, BEs of the Ti2p3/2 and Ti2p1/2 peaks in TiO2 were 458.8 eV and 464.4 eV and the Ti2p3/2 peak in Ti was at 453.5 eV. A previous report supports our Ti2p XPS spectra of TiO2 obtained from the Ti sensors. BEs of the Ti2p3/2 and Ti2p1/2 peaks in TiO2 are reported as 458.8 eV and 464.3 eV [27]. The BE of the Ti2p3/2 peak in metal Ti is reported as 454.1 eV [21]. XPS analysis did not detect the Au and Si elements of the gold electrode and the quartz crystal, respectively; thus, a thin uniform film might be formed onto the gold electrode of the quartz crystal.

3.3. Contact Angle Measurements

A cross-sectional view of a water droplet on the surface of the control, PMMA, and Ti QCM sensors and their contact angles are shown in Figure 6. It was found for the contact angles, which were °, °, and ° for the control, PMMA, and Ti QCM sensors, respectively. Several methods can be used to directly detect and quantify protein adsorption on a biomaterial [2830]. A QCM is a highly sensitive and practical device for in situ monitoring of protein adsorption. The amount of adsorption of BSA and BSM on the PMMA QCM sensors was higher than those achieved on the Ti and Au QCM sensors. The wettability of a material surface is an important factor for the adsorption of proteins, as determined by the protein adsorption principle. The water contact angle is a standard method for assessing the wettability of a material. The contact angle of PMMA was 101.7°, which shows that the PMMA surface is hydrophobic. However, the contact angle of PMMA was higher than those observed for the Ti and Au QCM sensors. It has been suggested that biomaterials with hydrophobic surfaces tend to adsorb proteins [1] and the high adsorption for PMMA might be related to the wettability of the material. Further studies are required to investigate the interactions between the QCM film sensors and protein, such as the surface potential and the protein function.

3.4. Adsorption Measurement of Bovine Salivary Proteins, BSA and BSM, Using Control, PMMA, and Ti QCM Sensors

The changes in frequency of the control, PMMA, and Ti QCM sensors on immersion into 2 mg/mL BSA and BSM solutions are shown in Figure 7. An immediate frequency decrease was observed after the injection of bovine salivary proteins. This decrease in frequency was related to the adsorption of bovine salivary proteins. In each case, adsorption is essentially completed within 30 min. The frequency shifts of the control, PMMA, and Ti QCM sensors with BSA were 644.1 Hz, 395.1 Hz, and 160.2 Hz, respectively. Therefore, according to the Sauerbrey equation, the amount of BSA adsorption was 399.3 ng cm−2, 250.0 ng cm−2, and 99.3 ng cm−2, respectively. The frequency shifts of the control, PMMA, and Ti QCM sensors with BSM were 545.8 Hz, 294.1 Hz, and 190.3 Hz, respectively. According to Sauerbrey equation, the amount of BSM adsorption was 338.4 ng cm−2, 182.3 ng cm−2, and 118.0 ng cm−2. The amounts of adsorption of BSA and BSM on the PMMA QCM sensors were the highest when compared with the other QCM sensors. Bacterial adhesion can be mediated by interaction with preadsorbed adhesive proteins but may also be affected, resulting in a greater risk of denture materials-related infections. A QCM is a highly sensitive and practical device for in situ monitoring of protein adsorption. In the present study, we fabricated the QCM sensors with denture materials to investigate the adsorption of salivary-related proteins on the denture surface.

3.5. XPS Analysis after Adsorption of Bovine Salivary Proteins

The XPS spectra of control, PMMA, and Ti QCM sensors after immersion in BSA are shown in Figures 8 and 9, and the three QCM sensors after immersion in BSM are shown in Figures 10 and 11. For XPS characterization, the C1s and N1s spectra were recorded. BEs of the C1s spectrum for adsorbed BSA were 285.0 eV (C-C/C-H), 285.9 eV (C-O/C-N), and 288.3 eV (O=C-O) for the control QCM sensors, 285.0 eV (C-C/C-H), 285.9 eV (C-O/C-N), and 288.0 eV (O=C-O) for the PMMA QCM sensors, and 285.0 eV (C-C/C-H), 286.4 eV (C-O/C-N), and 288.6 eV (O=C-O) for the Ti QCM sensors. There was an N1s peak for each of the three QCM sensors after adsorption of BSA. BEs of the C1s spectrum for adsorbed BSM were 285.0 eV (C-C/C-H), 286.1 eV (C-O/C-N), and 288.0 eV (O=C-O) in the control QCM sensors, 285.0 eV (C-C/C-H), 286.0 eV (C-O/C-N), and 287.5 eV (O=C-O) in the PMMA QCM sensors, and 285.0 eV (C-C/C-H), 286.1 eV (C-O/C-N), and 288.0 eV (O=C-O) in the Ti QCM sensors. After adsorption of the BSM, there were also N1s core-level spectra for the three QCM sensors. The structure and formation process of denture plaque is known to be the same as that for dental plaque and is composed of proteins and polysaccharides [27]. Endo et al. [31] demonstrated that C, O, and N derived from the organic material or metal oxide on the Au-In alloy surface were detected by XPS analysis. In this study, C1s and N1s spectra of the QCM sensor surface with adsorbed BSA and BSM were analyzed by XPS, and the C1s and N1s peaks derived from the BSA and BSM were detected on all QCM sensor surfaces tested. The quantification of the N1s peak arising from the peptide bonds of the salivary protein might be effective as a measure of the relative amount of protein adsorbed onto various surfaces.

4. Conclusion

We have fabricated highly stable denture material QCM sensors by spin-coating and magnetron sputtering methods. The SPM images show the relatively homogeneous surface with nano-order roughness. The XPS survey spectra of the thin films coated on the QCM sensors were quite similar to the BE observed from the characteristic spectra of the PMMA and Ti. Additionally, the amount of salivary-related protein on the PMMA QCM sensor was higher than those of Ti and Au QCM sensors and the differences of protein adsorption might be related to the wettability of each material. Our results support that the polymer denture surface exerts strong adhesion of microorganisms. In our pilot study, the addition of sodium dodecyl sulfate, which is an anionic, denaturating surfactant, increased the frequency shift of the PMMA/BSA QCM sensor. Further study will be required to investigate the removal of salivary-related protein using a chemical denture cleaner by real-time studies of the QCM.

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.

Acknowledgments

This study was partly supported by a Research Promotion Grant (15-05) from Osaka Dental University and a Grant-in-Aid for Scientific Research (26462943) from the Japan Society for the Promotion of Science. The authors thank Professor Koichi Imai and Mr. Hideaki Hori from the Central Institute of Dental Research, Osaka Dental University, Japan, and Mr. Yasuyuki Kobayashi from Osaka Municipal Technical Research Institute, Japan, for their encouragement and helpful suggestions. They thank Mr. Yasuyuki Nakanishi from OIKE & Co., Ltd., Japan, for help in the fabrication of the Ti QCM sensors. They are also grateful to the members of the Department of Removable Prosthodontics and Occlusion, Department of Biomaterials, and Department of Geriatric Dentistry for their kind advice and assistance.