Results of monotonic tensile test.
| Strength grade | Sample number | Yield stress (MPa) | Tensile stress (MPa) | Elongation (%) | Difference between yield point and nominal value (%) |
| Q345 | Number 1 | 387.2 | 496.6 | 22.2 | 12.2 | Number 2 | 383.3 | 485.5 | 24.4 | 11.1 | Number 3 | 385.5 | 492.6 | 23.5 | 11.7 | Mean | 385.3 | 491.6 | 23.4 | 11.7 |
| Q235 | Number 1 | 279.2 | 435.5 | 30.4 | 18.8 | Number 2 | 276.5 | 433.0 | 26.3 | 17.7 | Number 3 | 273.6 | 434.5 | 25.4 | 16.4 | Mean | 276.4 | 434.3 | 27.4 | 17.6 |
| LY160 | Number 1 | 160.2 | 262.2 | 30.9 | 0.0 | Number 2 | 165.1 | 266.1 | 33.4 | 3.2 | Number 3 | 164.5 | 260.4 | 30.6 | 2.8 | Mean | 163.3 | 262.9 | 31.6 | 2.0 |
|
|