Results of monotonic tensile test.

Strength gradeSample numberYield stress (MPa)Tensile stress (MPa)Elongation (%)Difference between yield point and nominal value (%)

Q345Number 1387.2496.622.212.2
Number 2383.3485.524.411.1
Number 3385.5492.623.511.7
Mean385.3491.623.411.7

Q235Number 1279.2435.530.418.8
Number 2276.5433.026.317.7
Number 3273.6434.525.416.4
Mean276.4434.327.417.6

LY160Number 1160.2262.230.90.0
Number 2165.1266.133.43.2
Number 3164.5260.430.62.8
Mean163.3262.931.62.0