Research Article

Concrete Pavement Service Condition Assessment Using Infrared Thermography

Table 1

Area comparison.

Number of pixelsIR measurement of areaPercentage of accuracy (POA)

Actual area of the defects inside the specimen302769 cm2100%
Area of processed image of the 5 mm deep defect212866.33 cm2 = 70.33%
Area of processed image of the 10 mm deep defect57271.7 cm2 = 18.88%