Research Article

Study on the Permeability Characteristics of Polyurethane Soil Stabilizer Reinforced Sand

Table 4

Results of porous permeability test.

NumberPSS concentrations
(%)
Sand depth
(cm)
Initial time (s)Water volume of 0–3 min (ml)Water volume of 3–6 min (ml)Water volume of 6–9 min (ml)Water volume of 9–12 min (ml)Water volume of 12–15 min (ml)

P-10%90108163.581152.471158.191164.671152.22
0%80/1113.691119.761110.971115.561122.39
0%70/1018.211081.891037.631047.711059.72
0%60/858.27871.75864.56853.86854.19
0%50/724.82733.72718.24720.44786.06
0%40/699.01710.60677.15702.00697.38
0%30/698.38676.47692.47691.87695.30
0%20/501.95508.12486.43469.03489.07
0%10/365.28419.73392.43383.27388.21

P-21%90305147.07277.42989.391062.421041.25
1%80/885.82865.74866.86880.41881.39
1%70/753.78762.15755.60777.70773.99
1%60/749.71754.97747.34758.36758.73
1%50/743.83734.2726.61737.77707.91
1%40/570.61569.03562.11553.26554.50
1%30/568.32574.71584.79544.77549.69
1%20/413.01395.92398.83392.69393.34
1%10/282.60293.46307.17286.12289.92

P-33%90150572.13329.33360.59360.39363.18
3%80/245.77334.64350.96357.55359.86
3%70/188.36292.52324.62348.77350.26
3%60/217.59303.63328.66346.53337.17
3%50/219.46296.48326.05338.52323.58
3%40/269.97301.23319.64313.52321.66
3%30/234.20267.63278.76292.08293.12
3%20/197.11213.06216.26213.55214.65
3%10/128.55129.40148.07144.43141.15

P-45%90720017.1935.5033.2433.4634.26
5%80/16.7530.0731.7432.3433.75
5%70/15.7230.7232.7532.7632.96
5%60/14.3629.6130.4830.1932.41
5%50/14.6129.6929.1328.5828.33
5%40/12.8828.6428.2527.5827.78
5%30/10.8924.4226.3426.4925.97
5%20/10.3621.0223.0422.2722.83
5%10/8.6219.1618.5318.4318.93