Advances in Materials Science and Engineering

Advances in Materials Science and Engineering / 2017 / Article
Special Issue

Failure Mechanisms and Damage Modelling for Advanced Materials

View this Special Issue

Research Article | Open Access

Volume 2017 |Article ID 6030357 | https://doi.org/10.1155/2017/6030357

Jose Vercher, Enrique Gil, Ángeles Mas, Carlos Lerma, M. Eugenia Torner, "Flexural Strengthening of Damaged T-Joists with Severe Corrosion Using CFRP Sheets", Advances in Materials Science and Engineering, vol. 2017, Article ID 6030357, 9 pages, 2017. https://doi.org/10.1155/2017/6030357

Flexural Strengthening of Damaged T-Joists with Severe Corrosion Using CFRP Sheets

Academic Editor: Francesco Caputo
Received27 Jan 2017
Accepted19 Feb 2017
Published12 Mar 2017

Abstract

This paper evaluates the residual safety of isolated T-joists with severe corrosion for the two extreme cases of boundary conditions, simply supported and fixed-ended, in order to help in making decisions about the magnitude of the necessary intervention. When the T-joist is part of a complete slab, the boundary conditions will be in an intermediate situation between these two extreme cases, so that it is possible to assess the safety with respect to its degree of embedding. The research is conducted for the cases of healthy T-joist, T-joist with complete corrosion of the lower reinforcement, and repaired T-joists with a variable number of CFRP sheets. This work is based on the ACI 318 load test to maintain a structure in use and proposes a Load Factor (LF), which estimates the safety reserve. The simply supported T-joists specimens with severe corrosion do not meet the Load Factor or ACI 318 criteria, even with a large number of CFRP sheets. On the other hand, fixed-ended cases can be kept in use despite corrosion by applying light CFRP strengthening, and with four sheets the initial safety is restored.

1. Introduction

The rehabilitation sector has achieved a greater importance than the construction of new buildings in recent years, due to the crisis in the construction of buildings. According to the Instituto de Tecnología de la Construcción [1], the forecasts for the coming years in Spain indicate that rehabilitation will be the sector with more activity (Figure 1). Because of this, it is essential to pay attention to the entire set of actions carried out in cases of rehabilitation.

But in the growing sector of rehabilitation, the flexural elements are the structural elements in which the higher percentages of damage appear. In Spain, lesions appear in 25.6% of the slabs, and corrosion in one-way slabs represents 68% of these cases [2].

In some cases of large damage, the severe corrosion of the lower level of tendons of a joist causes the spalling of the lower concrete cover. This effect is enhanced by the use of aluminous cement in prefabrication, widely used for a few decades because of its shorter time of manufacture. This occurs due to the conversion of this type of cement, since the concrete becomes more porous and attackable and less resistant [3]. In Spain, it is estimated that, of the 3,400,000 households built between 1950 and 1970, between 12 and 24% of them have used this type of cement in the slabs [4].

When the technicians analyze a case of structural pathology, they find the difficulty of assessing the remaining safety, in order to decide the magnitude of the intervention to be performed. This research quantifies the residual safety and helps to make this important decision.

Strengthening may be required when structures are damaged due to an aggressive environment. In these cases, the most common rehabilitation techniques have been accomplished by the use of conventional materials such as steel structural profiles (see Figure 2). However, recently the use of innovative materials like fiber-reinforced polymer (FRP) has emerged as an alternative to the use of the conventional techniques and it seems to be the most promising method to be used in structural engineering [5].

FRP is typically organized in a laminated structure, where each sheet contains an arrangement of unidirectional fibers or woven fiber fabrics embedded within a thin layer of light polymer matrix material. Fibers are typically composed of carbon, aramid, or glass. The matrix protects the fibers from damage and transfers the stresses between fibers. This matrix is commonly made of polyester, epoxy, or nylon. There are two additional types of FRP composite, bidirectional fibers, which are used commonly for strengthening two-way slabs, and the FRP rods, which became an alternative for reinforcement steel bars [6].

Externally bonded FRP reinforcement has been shown to be applicable for the strengthening of many types of reinforced concrete (RC) structures such as columns, beams, slabs, and walls and can be used to improve flexural and shear capacities [79] and also provide confinement and ductility to compression members [1012].

Externally bonded strengthening system, where the FRP sheets or plates are bonded to the concrete tensile surface, is widely used to improve the flexural capacity of concrete structures. Their application has multiple benefits, including increased ultimate flexural strength capacity and increased postcracking stiffness, as well as concrete crack control [13], high tensile strength, high durability, minimum increases in structural size and weight, ease of site handling, and good corrosion resistance. There are even some studies that aim to improve the properties of FRP sheets with carbon nanotubes or graphene nanoplatelets [14, 15]. Recently, near-surface-mounted technique was introduced, where the FRP bars of plates are inserted into a groove made in the concrete surface [16].

Although there are some authors who evaluate other types of FRP [17], the Carbon Fiber-Reinforced Polymer (CFRP) is mostly employed. There are numerous works which research about externally bonded CFRP reinforcement in order to strengthen many types of RC structures to resist higher design loads [1822], but there is less available research on corroded, patched, and CFRP-repaired RC specimens [23, 24].

Most of the work done by other authors is centered on isolated linear elements, usually beams, although there is some study of bidirectional elements like solid slabs [25]. There is no research on safety of joists inside a one-way slab. The aim of this research is to evaluate the residual safety increase of joists with a high degree of damage when they are part of a complete unidirectional slab, by gluing CFRP sheets on the underside. For this reason, specimens of isolated T-joists are assessed, with the different boundary conditions of usual modeling in structure analysis (simply supported and fixed-ended). When the joist is in a slab, its boundary conditions will be between these two extreme cases, so that we can assess its safety with respect to the degree of embedding that they have. This work focuses on the evaluation of slabs whose failure is dominated by flexion. This happens in most cases, because corrosion usually occurs in the lower reinforcement, due to it has less concrete cover.

2. Materials and Methods

Researchers have not made great efforts to accurately assess the remaining safety in cases of corrosion, in the field of building construction. The habitual action is to repair or reinforce, leaving the existing building on the side of safety.

The structural simplification of considering the actual three-dimensional elements such as lines does not represent the minimum balance of work with which they behave in reality. The loads are transmitted in various simultaneous forms in space. Mechanisms such as struts and ties or the arch effect appear in the elements subjected to flexion and contribute considerably if these elements have the horizontal displacement restrained. Because of this, it is necessary to study the elements in three dimensions, to properly assess the safety they possess.

2.1. Methodology for Assessing the Remaining Safety

The methodology used for the evaluation of the remaining safety of prestressed joists with severe corrosion and repaired with CFRP sheets is similar to the one the authors have developed in some publications of pathology in complete buildings [26], but in this case with CFRP strengthening. The novelty of this research is that it quantifies the remaining safety. Some healthy and damaged specimens of prestressed joist with compression layer (T-section) are simulated with ANSYS finite element software. With these simulations, the load-vertical displacement curves at midspan can be drawn. The proposed method to assess the remaining safety is based on the study of two aspects in these behavioral curves. First, the ACI 318 [27] load test for existing structures indicates whether a structure may continue in use and then the evaluation of the proposed Load Factor (LF).

According to ACI 318, the analyzed area must be loaded to 0.85 (), including dead load already present. is the sum of the dead loads, and is the total live load. Therefore, the total load value for the load test is equal to 9,435 N/m2 (see Table 1). If the deflection increase caused by the test satisfies , the specimen can continue in use, where is the span between supports (4.32 m in the present research) and is the specimen thickness (0.3 m). Thus, a deflection increase equal to 3.11 mm is allowed. When exceeding this limitation, retrieved deflection must be measured after the unloading. If the retrieved deformation is greater than 75%, the specimen is also accepted to continue in use.


Load (N/m2)
 Joist + compression layer dead load3,500
 Flooring + ceiling dead load1,000
 Partition walls dead load1,000
Total dead load5,500
 Quasipermanent live load600
 Service load6,100
Total live load2,000
Total standard load7,500

ACI 318 load test
 Load9,435
 Deflection increase limitation (mm)3.11

And when it has been found that the slab can remain in use, the Load Factor is analyzed in order to quantify the remaining safety and the magnitude of the necessary intervention. This factor is obtained making the ratio between the load at which each specimen reaches the permissible active deflection for the partition walls and the total standard load (total dead load + total live load). The LF relates the load that each model bears and the total load that they must bear, according to standards. According to the Spanish code on structural concrete [28], the limitation on the permissible active deflection for the partition walls of is given, being the span. In this research, this value is 1.08 cm. This deflection occurs from the moment that the partition walls are constructed. A vertical displacement of 1.08 cm is allowed from this moment, and the supported load in each specimen is related to the total standard load.

2.2. Specimens Geometry

Nonlinear simulations of prestressed T-joists throughout their load range were performed using the finite element method (FEM). The T-joist models are very accurate, with the real 3D geometry and the reinforcement in its exact position (Figure 3). The simulated joist is part of a one-way slab of 30 cm thickness with a span of 4.92 m between column axes, with flat beams of 60 cm width. Therefore the joist length is 4.32 m.

The compression layer is centered on the joist and has 69 cm width, because it is the spacing between joists in the one-way slab, and 5 cm thickness. The reinforcement mesh inside the compression layer is composed of a 6 mm rod every 24 cm in both directions. The filler blocks are not simulated because they are not resistant elements. The prestressed joist is the T12.3 model of the Spanish company Prevalesa S. L., with four 5 mm prestressed tendons on three levels. The middle and the upper level have one tendon, simulated as two half tendons in order to keep the section symmetry in the simulations.

This research work comprises 12 T-joist specimens, in which the influence of the boundary conditions, the damage level, and the CFRP strengthening are assessed. Simply supported models are from (A1) to (A6) specimens, and fixed-ended joists models are presented in (B1) to (B6) specimens. As previously stated, when a T-joist is part of a complete building, it does not behave in any of these two ways, because it is in an intermediate position between full restrain and freedom. In order to assess the increased safety in damaged joists with CFRP repair, there are six variants: healthy, extreme corrosion without CFRP repair, with 1, 2, 3, and 4 CFRP sheets.

2.3. Process of Loads and Constructive Elements

The strict simulation of the process of loads and order of appearance of structural and building elements is very important, in order to capture the behavior and get the closest results to the actual situation when the joist is part of a complete building.

The simulated steps, which correspond with real steps in the constructive process and are summarized in Table 1, are the following:(i)Prestressed joist: in a first step, only the prestressed joist is simulated, and therefore at this point only these elements are active. The prestress is introduced as equivalent prestressing forces at the corresponding points. The equivalent force per 5 mm diameter rebar is equal to 17,000 N, after a 29% loss over infinite time. At the end of this step, the joist has a negative deflection, as in reality.(ii)Structural dead load: in a second step, the concrete is poured in situ in order to complete the slab thickness and the compression layer.(iii)Flooring and ceiling dead load: these constructive elements appear in this moment and are simulated as a load increment of 1,000 N/m2.(iv)Partition walls dead load: now, the partition walls appear as a dead load increment of 1,000 N/m2. The active deflection with respect to the partition walls will start as soon as this load is completely added. This deflection is limited to 1.08 cm in the assessed specimens, due to their length.(v)Service load: when the building is finished, the T-joist is supporting the service load. The service load is the load to which the structure will be subjected most of its useful life. It consists of the dead loads and the quasipermanent part of the live load, according to the standard CTE-06 [29]. The characteristic value of the live load for housing in Spain is 2,000 N/m2, and the quasipermanent value is 600 N/m2.(vi)Corrosion: corrosion damage appears during the service life. The most severe pathological cases are assessed in this research. Therefore, the corrosion is modeled as the removal of the lower level of prestressed tendons and the concrete cover spalling, as it may occur in some extreme cases. But the other two levels of prestressed tendons are maintained, because they continue to assist in supporting the joist. The assessment of the most severe cases provides the lowest value of failure load, so that it is on the side of safety. Due to their boundary conditions, simply supported specimens experience a large vertical displacement at midspan if the disappearance of the lower tendons and concrete cover is simulated to the load corresponding to the service load (6,100 N/m2). Because of this, corrosion was simulated to a lower load value in these cases (4,000 N/m2), and from this point, the following load steps were loaded successively as explained in this part. This consideration does not affect the results of the research, since the objective is to assess residual safety and achieve adequate safety at the end.(vii)CFRP sheet: the prefabricated sheets are bonded to the tension side of the specimens after sandblasting, brushing, and cleaning the concrete surface to guarantee a good bond between the adhesive and the concrete [30]. The choice and placement of the CFRP sheet must follow the ACI Committee 440 guidelines [31].(viii)Total standard load: at this point, the specimens are loaded with the total live load, in order to reach the total standard load. This is the total load that the slab must support according to standards.(ix)Load until failure: finally, the T-joist is loaded until collapse.

2.4. Materials

For the T-joist specimens, the simulation of the behavior of five materials is needed: two types of concrete and two types of steel and the CFRP sheet. Because the joists are prefabricated and the rest of the reinforced concrete T-joist is constructed in situ, different qualities of both steel and concrete appear. The assessed prestressed joist is the T12.3 model of the Spanish company Prevalesa S. L., with four 5 mm prestressed tendons on three levels. HP-40 concrete and Y-1860-C high performance prestressing steel form precast joists. Instead, the concrete in situ is the commonly used HA-30 and the steel reinforcements are made with B-500-SD steel. In addition, CFRP sheets are placed to repair damaged specimens. The chosen CFRP sheet for this research work is MAPEI MapeWrap C UNI-AX 300/10 with 0.166 mm thickness. Table 2 summarizes the mechanical properties of the employed materials.


Material
ConcreteSteelCFRP
HA-30HP-40B-500-SDY-1860-C

Density (kN/m3)252578.578.5
Elastic modulus (GPa)28.630.9200200230
Compression strength (MPa)3848
Tensile strength (MPa)3.393.964850
Poisson’s ratio0.20.20.30.3
Yielding strength (MPa)5001581
Ultimate strain0.02
Element typeSOLID65SOLID65LINK180Prest. FSHELL181

2.5. Finite Element Model

The finite element method (FEM) is conducted to simulate the behavior of the test specimens in ANSYS software. The investigated T-joist specimens were developed in three-dimensional models in order to account for the materials nonlinear behavior.

Eight-node solid brick elements (Solid65) were used to simulate the concrete. This solid is capable of cracking in tension and crushing in compression, creep nonlinearity, and large deflection geometrical nonlinearity. The concrete requires multilinear isotropic material properties and the Willam-Warnke [32] spatial failure criteria to properly model its behavior. The uniaxial stress-strain relation was defined by the civil engineering Eurocode. Two simulation techniques have been used for steel reinforcements. The prestressed bars of the precast joist are introduced as equivalent prestressing forces at the corresponding points, and 3D spar elements (Link180) were employed to simulate the reinforcement mesh inside the compression layer. This three-dimensional element is a uniaxial tension-compression element with three degrees of freedom at each node. Plasticity, creep, swelling, stress stiffening, and large deflection capabilities are included. The steel is assumed to be an elastic-perfectly plastic material and identical in tension and compression, and its behavior can be simplified by an isotropic bilinear curve. And finally, a shell element (Shell181) was used to simulate the CFRP sheets. It is a four-node 3D element with six degrees of freedom at each node and is well-suited for linear, large rotation, and/or large strain nonlinear applications. The CFRP-material is considered as linear elastic until failure. This type of element needs a failure criterion for the complete definition of behavior. The physical failure criteria are specially formulated to account for different damage mechanisms (fiber and matrix failure) in fiber-reinforced composite materials. Hashin maximum stress failure criteria were used in this research [33] for the CFRP sheets. To complete the material damage definition, it is also necessary to specify a compatible damage initiation criteria and evolution law. Progressive damage evolution based on continuum damage mechanism was chosen. In this case, energies dissipated per unit area are specified individually for all damage modes (fiber tension, fiber compression, matrix tension, and matrix compression). For a specific damage mode, is given bywhere is the equivalent stress, is the equivalent displacement, and is the ultimate equivalent displacement, where total material stiffness is lost for the specific mode [34]. For complex stress state, the equivalent stresses and strains are calculated based on Hashin failure criteria. Viscous damping coefficients η are also specified respectively for all four damage modes. For a specific damage mode, the damage evolution is regularized as follows:where is the regularized damage variable at current time, is the regularized damage variable at the end of the last substep, and is the unregularized current damage variable [34].

Half of the T-joist specimen has been simulated, seeking to optimize computing time. Therefore, it was necessary to simulate suitable boundary conditions to behave in the same manner as the complete T-joist. The simulated boundary conditions were of symmetry at the midspan, allowing the vertical displacement and roller support or embedding in the end, according to the assessed model. A total of 5679 elements were required for T-joist analysis (5040 3D elements, 423 link elements, and 216 shell elements). The total nodes of each specimen were 7592. Most of the concrete elements are a prism with 30 × 30 × 30 mm. The choice of mesh size was based on preliminary studies in which different sizes were used [35]. This number of elements represents a good balance between the computational time and the numerical accuracy of results.

The Newton-Raphson equilibrium iterations were used in the nonlinear solutions. Convergence criteria for the specimens were based on force and displacement. The convergence tolerance limits were selected by analysis program [36].

In this study, a perfect bond between concrete and steel was assumed. The nodes of the CFRP elements are also connected to those of adjacent concrete elements [37]. The interaction between the concrete joist and the CFRP is modeled without considering debonding. The bond does not have to be explicitly modeled in the numerical analysis [38].

The ANSYS software allows the generation of load steps and the birth and death of elements in the different steps. The cases of corrosion evaluated in this work are the most severe, involving the total loss of the concrete cover and the lower level of tendons. Therefore, corrosion is simulated in the model by the death of the elements constituting the cover and the lower reinforcement in the proper load step.

2.6. Model Verification

A very careful calibration of the numeric simulations has been made in order to verify the accuracy of the used hypothesis and models regarding the behavior of CFRP sheets. The FE software is used to predict the flexural behavior of strengthened beams reported by Esfahani et al. [39] in order to validate the research methodology and its results and final conclusions.

For the Esfahani et al. specimens, the design compressive strength of 25 MPa was used for concrete and different sizes of reinforcing bars were used in specimens. The yield and ultimate strength of different bars are given in Table 3. The mechanical properties of CFRP are the following: the ultimate strain is 0.012, the tensile strength is 2845 MPa, and the modulus of elasticity is 237 GPa. Reaction force versus CFRP strain relationship in simulated sheet can be seen in Figure 4.


Bar diameter (mm)81016
Yielding stress (MPa)350365406
Ultimate stress (MPa)459572583

The specimens (B5) and (B7) were selected. The dimensions details of the beam are shown in Figure 5. The 8 mm steel rods are employed for stirrups each 80 mm. The nominal thickness and width of the CFRP were 0.176 mm and 150 mm, and the specimen (B7) was strengthened with one CFRP sheet.

All specimens have been reproduced successfully in FE software. A good correspondence in the behavior of the different models has been achieved, following their specifications when performing the simulations. A great concordance in the load-displacement curves has been obtained in all cases. In Figure 6 the B5 and B7 specimens are shown, as an illustrative example, where it can be seen that our work improves the correlation between the results of the analytical and the experimental study. The validated results are consistent in all models, so that both the software and the materials properties are accepted as valid tools for the research.

3. Results and Discussion

The prestressed T-joists simulation throughout their load range has been performed. Load-vertical displacement plots at midspan are compared in healthy, corroded, and repaired models in order to assess the residual safety. Figures 7 and 8 represent the load-vertical displacement at midspan relationships for the 12 specimens. Table 4 shows the load at permissible active deflection, the Load Factor (LF) values, and ACI 318 load test results for simulated specimens.


SpecimenLoad at permissible active deflection (N/m2)Load Factor (LF)ACI 318 load test

Simply supported joist(A1)Healthy9,9841.33Right
(A2)Corroded without repair5,2160.70Negative
(A3)Corroded with 1 CRRP sheet5,9600.79Negative
(A4)Corroded with 2 CRRP sheets7,0850.94Negative
(A5)Corroded with 3 CRRP sheets8,1071.08Negative
(A6)Corroded with 4 CRRP sheets9,0801.21Negative

Fixed-ended joist(B1)Healthy18,6852.49Right
(B2)Corroded without repair14,5201.93Right
(B3)Corroded with 1 CRRP sheet15,7062.09Right
(B4)Corroded with 2 CRRP sheets16,8742.26Right
(B5)Corroded with 3 CRRP sheets17,5892.33Right
(B6)Corroded with 4 CRRP sheets18,0962.42Right

Several aspects can be seen in a deep analysis of the load-vertical displacement curves, which are as follows:(i)The initial precamber produced by the process of prestressing in prefabrication.(ii)The horizontal stretch due to corrosion: the end of this step is the starting point for the simulation of the load test acceptance criterion of existing structures proposed by the ACI 318. For simply supported specimens, it must be remembered that cases with severe corrosion have a large vertical displacement if corrosion appears at 6100 N/m2, so that the corrosion has been simulated to a load of 4000 N/m2. But load test is correctly performed from the service load, with the deflection that the T-joist would have in service life with pathology. The Load Factor has also been obtained with the permissible active deflection from the appearance of the partition walls.(iii)ACI 318 load test evaluation: this test determines whether a structure can remain in use, and its compliance is graphically analyzed in Figures 7 and 8. The procedure consists of limiting graphically the service load and ACI 318 load test and then also limiting the allowed deflection increase.(iv)Load Factor: the load supported at permissible active deflection for the partition walls and the standard load can be analyzed in Figures 7 and 8 and graphically understand the relationship with which the Load Factor is obtained.Simply supported damaged specimens do not withstand the loads established by Building Technical Code CTE-06 [40] with less than 3 CFRP sheets ((A2), (A3), and (A4) specimens), so they have a Load Factor of less than 1. A safety coefficient of 1.08 and 1.21 was obtained with 3 and 4 sheets, respectively ((A5) and (A6) specimens), remaining with an unacceptable safety in structure analysis. In addition, no simply supported damaged specimen meets the criteria for continue in use of the ACI 318, even with 4 CFRP sheets. Severe corrosion in the simply supported specimen causes a 47.4% reduction in the ultimate capacity of the T-joist. The inclusion of CFRP sheets improves the bearing capacity of the specimen with respect to the damaged joist without repair as follows: +12.9% with 1 sheet, +34.3% with 2 sheets, +54.3% with 3 sheets, and +72.9% with 4 sheets, not reaching initial safety.

Fixed-ended damaged T-joist without repair ((B2) specimen) support the loads established by the standard with a safety coefficient of 1.93, almost double of the standard load (dead loads + live loads). When gluing one CFRP sheet, the Load Factor 2 is exceeded, and with 2, 3, and 4 sheets, the safety coefficients of 2.26, 2.33, and 2.42, respectively, are reached. All studied fixed-ended specimens can continue in use according to ACI 318. The complete corrosion of the lower level of tendons and the loss of the concrete cover in the fixed-ended specimen causes a 22.5% reduction in the ultimate capacity. The capacity of the severe damaged T-joist is improved with the inclusion of CFRP sheets as follows: +8.3% with 1 sheet, +17.1% with 2 sheets, +20.7% with 3 sheets, and +25.4% with 4 sheets, getting close to recovering initial safety.

Severe corrosion reduces the ultimate capacity of the simply supported T-joists in a more noticeable way. But, on the other hand, the addition of CFRP sheets improves to a greater extent the capacity of this type of joists.

The regulations establish clear safety coefficients for the calculation of structures in new construction, where they have a great control of the materials and the processes of construction. The acceptable Load Factor in cases of rehabilitation remains the responsibility of the expert performing the project and depends on local standards. Anyway, it seems sensible to assume a value near 2 as a minimum, depending on the reliability of the materials tests.

4. Conclusions

The actual boundary conditions of a T-joist when it is part of an entire one-way slab are in an intermediate case of restriction on the ends, neither totally free nor totally restrained. The evaluation of the two extreme theoretical cases presented in this paper is very important because it allows the technician to establish some actuation limits.

Cases of severely damaged simply supported T-joist do not support the service load without the help of neighboring joists. The added stiffness by strengthening with CFRP sheets with low thickness does not solve the problem, and it can not be accepted as constructive solution. Vertical displacement can not be controlled according to EHE-08 [28], even in the case with the addition of 4 CFRP sheets. Damaged simply supported specimens do not meet the ACI 318 load test to maintain the structure in use, not even with 4 CFRP sheets. Perhaps proper safety can be reached with a higher number of sheets, but it is not a common solution. The most common cases in actual practice are in which one or two sheets are used. Load Factor assessment indicates that none of the repairs reaches an acceptable safety, notwithstanding the loads with the safety factors established by the standards. Our experience tells us that if there is a group of contiguous and hardly damaged joists in a one-way slab, the loads transmission perpendicular to joists force them to collaborate one with each other. Despite the damage in the lower tendons, damage may not appear in the rest of construction elements in some cases. But even if the damage does not appear on the other elements, an immediate shoring up and deep repair are necessary.

The boundary conditions in the cases of fixed-ended T-joists are theoretical. This degree of embedment is attainable in the central bays of slabs with a large symmetry of spans or with a very small difference in lengths. It is remarkable that in the evaluated real cases of this type of slab it can be seen that in spite of a great deterioration in the joists no cracking or damage appears in the other elements of the building. This can be understood watching the simulations of these cases with severe corrosion, where the vertical displacement at midspan with heavy loads remains small in magnitude. The ACI 318 load test for these cases of isolated T-joist with a span of 4.32 m indicates the meeting of all safety criteria. The simulation of the load test in these specimens gives vertical displacements around 30% of standard limitation, because the boundary conditions maintain a high stiffness, even with a severe degree of corrosion. The Load Factor for all these cases exceeds the safety factors proposed by standards. It is noted that the case with four CFRP sheets recovers the initial safety.

Conflicts of Interest

The authors declare that there are no conflicts of interest regarding the publication of this paper.

References

  1. Instituto de Tecnología de la Construcción (ITeC), Informe Euroconstruct, Instituto de Tecnología de la Construcción, Barcelona, Spain, 2015.
  2. J. A. Vieitez Chamosa and J. L. Ramírez Ortiz, “Patología de la construcción en España: aproximación estadística,” Informes de la Construcción, vol. 36, no. 364, pp. 5–15, 1984. View at: Publisher Site | Google Scholar
  3. Instituto Valenciano de la Edificación (IVE), Guía para la Inspección y Evaluación Preliminar de Estructuras de Hormigón en Edificios Existentes, Serie Guías de la Calidad, Generalitat Valenciana—Conselleria de Medi Ambient, Aigua, Urbanisme i Habitatge, Valencia, Spain, 2008.
  4. Instituto Valenciano de la Edificación (IVE), Experiencia en Inspección de Estructuras en Edificios. Comunidad Valenciana 1991–2008, Serie Guías de la Calidad, Generalitat Valenciana-Conselleria de Medi Ambient, Aigua, Urbanisme i Habitatge, Valencia, Spain, 2008.
  5. L. Anania, A. Badalà, and G. Failla, “Increasing the flexural performance of RC beams strengthened with CFRP materials,” Construction and Building Materials, vol. 19, no. 1, pp. 55–61, 2005. View at: Publisher Site | Google Scholar
  6. F. A. Fathelbab, M. S. Ramadan, and A. Al-Tantawy, “Strengthening of RC bridge slabs using CFRP sheets,” Alexandria Engineering Journal, vol. 53, no. 4, pp. 843–854, 2014. View at: Publisher Site | Google Scholar
  7. A. Khalifa and A. Nanni, “Improving shear capacity of existing RC T-section beams using CFRP composites,” Cement and Concrete Composites, vol. 22, no. 3, pp. 165–174, 2000. View at: Publisher Site | Google Scholar
  8. H. M. Tanarslan, “The effects of NSM CFRP reinforcements for improving the shear capacity of RC beams,” Construction and Building Materials, vol. 25, no. 5, pp. 2663–2673, 2011. View at: Publisher Site | Google Scholar
  9. J. Dong, Q. Wang, and Z. Guan, “Structural behaviour of RC beams with external flexural and flexural-shear strengthening by FRP sheets,” Composites Part B: Engineering, vol. 44, no. 1, pp. 604–612, 2013. View at: Publisher Site | Google Scholar
  10. H. Toutanji, M. Han, J. Gilbert, and S. Matthys, “Behavior of large-scale rectangular columns confined with FRP composites,” Journal of Composites for Construction, vol. 14, no. 1, pp. 62–71, 2010. View at: Publisher Site | Google Scholar
  11. B. Csuka and L. P. Kollár, “Analysis of FRP confined columns under eccentric loading,” Composite Structures, vol. 94, no. 3, pp. 1106–1116, 2012. View at: Publisher Site | Google Scholar
  12. C. Desprez, J. Mazars, P. Kotronis, and P. Paultre, “Damage model for FRP-confined concrete columns under cyclic loading,” Engineering Structures, vol. 48, pp. 519–531, 2013. View at: Publisher Site | Google Scholar
  13. A. M. Ceci, J. R. Casas, and M. Ghosn, “Statistical analysis of existing models for flexural strengthening of concrete bridge beams using FRP sheets,” Construction and Building Materials, vol. 27, no. 1, pp. 490–520, 2012. View at: Publisher Site | Google Scholar
  14. F. Inam, D. W. Y. Wong, M. Kuwata, and T. Peijs, “Multiscale hybrid micro-nanocomposites based on carbon nanotubes and carbon fibers,” Journal of Nanomaterials, vol. 2010, Article ID 453420, 12 pages, 2010. View at: Publisher Site | Google Scholar
  15. M.-Y. Shen, T.-Y. Chang, T.-H. Hsieh et al., “Mechanical properties and tensile fatigue of graphene nanoplatelets reinforced polymer nanocomposites,” Journal of Nanomaterials, vol. 2013, Article ID 565401, 9 pages, 2013. View at: Publisher Site | Google Scholar
  16. H. T. Choi, J. S. West, and K. A. Soudki, “Partially bonded near-surface-mounted CFRP bars for strengthened concrete T-beams,” Construction and Building Materials, vol. 25, no. 5, pp. 2441–2449, 2011. View at: Publisher Site | Google Scholar
  17. N. Attari, S. Amziane, and M. Chemrouk, “Flexural strengthening of concrete beams using CFRP, GFRP and hybrid FRP sheets,” Construction and Building Materials, vol. 37, pp. 746–757, 2012. View at: Publisher Site | Google Scholar
  18. Y. Shen, S. Lu, and F. Li, “An experimental study on concrete flat slabs prestressed with carbon fibre reinforced polymer sheets,” Advances in Materials Science and Engineering, vol. 2015, Article ID 792320, 11 pages, 2015. View at: Publisher Site | Google Scholar
  19. M. M. Önal, “Strengthening reinforced concrete beams with CFRP and GFRP,” Advances in Materials Science and Engineering, vol. 2014, Article ID 967964, 8 pages, 2014. View at: Publisher Site | Google Scholar
  20. J. F. Bonacci and M. Maalej, “Behavioral trends of RC beams strengthened with externally bonded FRP,” Journal of Composites for Construction, vol. 5, no. 2, pp. 102–103, 2001. View at: Publisher Site | Google Scholar
  21. S. T. Smith and J. G. Teng, “FRP-strengthened RC beams. I: review of debonding strength models,” Engineering Structures, vol. 24, no. 4, pp. 385–395, 2002. View at: Publisher Site | Google Scholar
  22. A. F. Ashour, S. A. El-Refaie, and S. W. Garrity, “Flexural strengthening of RC continuous beams using CFRP laminates,” Cement and Concrete Composites, vol. 26, no. 7, pp. 765–775, 2004. View at: Publisher Site | Google Scholar
  23. H. K. Lee and L. R. Hausmann, “Structural repair and strengthening of damaged RC beams with sprayed FRP,” Composite Structures, vol. 63, no. 2, pp. 201–209, 2004. View at: Publisher Site | Google Scholar
  24. A. H. Al-Saidy and K. S. Al-Jabri, “Effect of damaged concrete cover on the behavior of corroded concrete beams repaired with CFRP sheets,” Composite Structures, vol. 93, no. 7, pp. 1775–1786, 2011. View at: Publisher Site | Google Scholar
  25. S. Pirayeh Gar, J. B. Mander, M. Head, and S. Hurlebaus, “FRP slab capacity using yield line theory,” Journal of Composites for Construction, vol. 18, no. 6, 2014. View at: Publisher Site | Google Scholar
  26. J. Vercher, E. Gil, A. Mas, and C. Lerma, “Diagnosis and intervention criteria in slabs damaged by severe corrosion of prestressed joists,” Journal of Performance of Constructed Facilities, vol. 29, no. 1, 2015. View at: Publisher Site | Google Scholar
  27. ACI Committee 318, ACI 318-08: Building Code Requirements for Structural Concrete and Commentary. Strength Evaluation of Existing Structures, American Concrete Institute, Detroit, Mich, USA, 2008.
  28. Ministerio de Fomento, EHE-08: Instrucción de Hormigón Estructural, Boletín Oficial del Estado, Madrid, Spain, 2008.
  29. Ministerio de Vivienda, CTE-06: Código Técnico de la Edificación, Boletín Oficial del Estado, Madrid, Spain, 2006.
  30. G. Camata, E. Spacone, and R. Zarnic, “Experimental and nonlinear finite element studies of RC beams strengthened with FRP plates,” Composites Part B: Engineering, vol. 38, no. 2, pp. 277–288, 2007. View at: Publisher Site | Google Scholar
  31. ACI Committee 440, ACI 440.2R-08: Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures, American Concrete Institute, Detroit, Mich, USA, 2008.
  32. K. J. Willam and E. D. Warnke, “Constitutive model for the triaxial behavior of concrete,” in Proceedings of the International Association for Bridge and Structural Engineering (ISMES '75), vol. 19, p. 30, Bergamo, Italy, 1975. View at: Google Scholar
  33. Z. Haszin, “Failure criteria for unidirectional fiber composites,” Journal of Applied Mechanics, Transactions ASME, vol. 47, no. 2, pp. 329–334, 1980. View at: Publisher Site | Google Scholar
  34. ANSYS Academic Research, Release 15.0, ANSYS Help, ANSYS, Inc.
  35. J. Vercher, E. Gil, and A. Mas, Load-Bearing Capacity of Corroded Reinforced Concrete Joists, Structures and Architecture: Concepts, Applications and Challenges, Taylor & Francis Group, London, UK, 2013.
  36. Y. Zhou, M. Gou, F. Zhang, S. Zhang, and D. Wang, “Reinforced concrete beams strengthened with carbon fiber reinforced polymer by friction hybrid bond technique: experimental investigation,” Materials and Design, vol. 50, pp. 130–139, 2013. View at: Publisher Site | Google Scholar
  37. A. Agbossou, L. Michel, M. Lagache, and P. Hamelin, “Strengthening slabs using externally-bonded strip composites: analysis of concrete covers on the strengthening,” Composites Part B: Engineering, vol. 39, no. 7-8, pp. 1125–1135, 2008. View at: Publisher Site | Google Scholar
  38. O. Enochsson, J. Lundqvist, B. Täljsten, P. Rusinowski, and T. Olofsson, “CFRP strengthened openings in two-way concrete slabs—An Experimental And Numerical Study,” Construction and Building Materials, vol. 21, no. 4, pp. 810–826, 2007. View at: Publisher Site | Google Scholar
  39. M. R. Esfahani, M. R. Kianoush, and A. R. Tajari, “Flexural behaviour of reinforced concrete beams strengthened by CFRP sheets,” Engineering Structures, vol. 29, no. 10, pp. 2428–2444, 2007. View at: Publisher Site | Google Scholar
  40. Ministerio de Vivienda, Código Técnico de la Edificación (CTE), Boletín Oficial del Estado, Madrid, Spain, 2006.

Copyright © 2017 Jose Vercher et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


More related articles

 PDF Download Citation Citation
 Download other formatsMore
 Order printed copiesOrder
Views856
Downloads325
Citations

Related articles

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.