Research Article
Experimental Investigation of the Effects of Concrete Alkalinity on Tensile Properties of Preheated Structural GFRP Rebar
Table 2
Tensile strength and elastic modulus.
| Specimen ID | Mean (MPa) | SD (MPa) | CoV (%) | 0 days | 100 days | 300 days | 660 days | 0 days | 100 days | 300 days | 660 days | 0 days | 100 days | 300 days | 660 days |
| ā | Tensile strength | Ref | 644.7 | 574.8 | 183.0 | 114.9 | 24.3 | 47.7 | 8.7 | 29.3 | 3.8 | 8.3 | 4.7 | 25.5 | PH_120 | 643.7 | 582.0 | 162.8 | 125.6 | 38.4 | 60.2 | 29.9 | 23.9 | 6.0 | 10.3 | 18.4 | 31.9 | PH_200 | 612.8 | 503.7 | 159.6 | 120.7 | 27.6 | 47.7 | 18.0 | 17.1 | 4.5 | 9.5 | 11.3 | 14.1 |
| ā | Elastic modulus | Ref | 53.4 | 52.0 | 17.6 | 16.4 | 6.8 | 3.9 | 1.7 | 2.7 | 12.7 | 7.4 | 9.8 | 16.5 | PH_120 | 52.0 | 51.0 | 16.2 | 16.0 | 3.0 | 3.2 | 1.7 | 2.1 | 5.7 | 6.3 | 10.3 | 13.1 | PH_200 | 50.2 | 49.6 | 16.4 | 15.2 | 3.5 | 3.8 | 1.3 | 2.2 | 6.9 | 8.0 | 7.6 | 14.2 |
|
|