Research Article

Optimal Heat Transfer Coefficient Distributions during the Controlled Cooling Process of an H-Shape Steel Beam

Table 2

The optimization search of distribution for Case  2 (e.g., with ten points).

Number
W/m2KW/m2KW/m2KW/m2KW/m2K°C°C

(1) (constant)1400140014001400140548204
(2)1340144914501419100548198
(3)136514531452142099549192
(4)131514601458142198551178
(5)128914641461142196553172
(6)121314821475146592555151
(7)118115451485148667556142
(8)113316101550147764558136
(9)110916101555145644559132
(10) (optimization)109117051666144537560130