Influence of the cutoff filter frequency on the first-moment fault location error,  = 100 km.

 (Hz)200500100020005000

Method 16049.2824.283.432.78
Method 277.8580.7162.1442.8532
Method 3102.170.7134.287.140.44
Method 460.757.1421.427.1−1.2