Influence of the cutoff filter frequency on the error of average fault location result,  = 100 km.

 (Hz)200500100020005000

Method 10.0350.0620.0710.720.071
Method 20.140.090.0581.020.14
Method 30.510.50.4281.050.5
Method 4−1.51−2.34−1.42−2.34−1.6