Research Article
The Impact Toughness and Hardness of Treated and Untreated Sisal Fibre-Epoxy Resin Composites
Table 1
Values of impact toughness for pure epoxy as well as treated and untreated sisal fibre-epoxy resin composites.
| Weight % of the reinforcing fibre | Impact energy of untreated sisal fibre-epoxy resin composites | Impact energy of treated sisal fibre-epoxy resin composites | % increase of impact energy | Range (joules) | Average (joules) | Coefficient of variation (%) | Range (joules) | Average (joules) | Coefficient of variation |
| Epoxy (0) | 0.54–1.22 | 0.84 ± 0.24 | 28.33 | 0.54–1.22 | 0.84 ± 0.24 | 28.33 | — | 5 | 0.81–1.89 | 1.14 ± 0.29 | 25.47 | 1.63–2.44 | 2.14 ± 0.29 | 13.48 | 28.09 | 10 | 2.30–2.71 | 2.50 ± 0.12 | 14.86 | 1.08–4.75 | 2.96 ± 0.93 | 31.59 | 20.07 | 15 | 1.36–4.61 | 3.47 ± 0.86 | 24.81 | 2.03–5.56 | 3.96 ± 0.84 | 21.32 | 14.06 | 30 | 5.28–7.86 | 6.54 ± 0.67 | 22.45 | 6.34–8.15 | 7.55 ± 0.67 | 25.47 | 15.44 | 50 | 8.76–11.74 | 10.34 ± 0.74 | 18.44 | 10.77–13.15 | 12.65 ± 0.82 | 25.22 | 22.34 |
|
|