Research Article

Repairing 2024 Aluminum Alloy via Electrospark Deposition Process: A Feasibility Study

Table 7

Tensile test for the as-received BM in T4 and T6 states, as-received BM notched, the untreated repaired samples, and heat-treated T135_2 and T190_6 repaired samples.

Sampleσy (MPa)Fy (N)UTS (MPa)Maximum load (N)ef (%)S0 (mm2)

2024-T43398315.748511,8932924.53
2024-T4 notched3467480.5250310,87713.321.62
2024-T4 notched T135_2213.34645.7487.210610.91221.78
2024-T4 repaired2576198.844029696.24924.12
2024-T4 repaired + T135_22917245.941910,44010.124.9
2024-T4 repaired + T190_6329.27966.64442.510,202.25.5124.2
2024-T648211,852.451612,69116.424.59
2024-T6 notched48210,488.353211,5854.521.76
2024-T6 repaired3728965.243910,579.9424.1
2024-T6 repaired + T135_24119913.3245510,9734.224.12
2024-T6 repaired + T190_6418.810,302.5457.2911,238.63.2424.6