Experimental values of the densities ρ, speeds of sound c, and refractive indices nD at various temperatures T and specific concentrations C of AC for the system AC + THF.a

T (K)ρ (kg·m−3)c (m·s−1)nDρ (kg·m−3)c (m·s−1)nD

C (kg·m−3) = 0C (kg·m−3)  = 20
293.15887.621303.651.40731887.661303.611.40731
298.15882.161279.381.40464882.211279.461.40465
303.15876.641255.241.40198876.681255.311.40200
308.15871.141231.101.39932871.181231.191.39935
C (kg·m−3) = 40C (kg·m−3) = 60
293.15887.721303.591.40731887.761303.621.40732
298.15882.231279.521.40466882.291279.581.40467
303.15876.741255.371.40201876.801255.411.40202
308.15871.211231.261.39936871.271231.371.39938
C (kg·m−3) = 80C (kg·m−3) = 100
293.15887.801303.721.40733887.871303.721.40733
298.15882.341279.641.40468882.411279.641.40468
303.15876.851255.491.40203876.911255.491.40203
308.15871.321231.461.39938871.391231.461.39938

aC (kg·m−3) is the specific concentration of AC in the THF solvent. Standard uncertainties (u) are u(T) = 0.001 K for ρ and c and u(T) = 0.01 K for nD, and the combined expanded uncertainties (Uc) are Uc(ρ) = 0.01 kg·m−3, Uc(c) = 0.05 m·s−1 (level of confidence = 0.95, k = 2), and Uc(nD) = 0.00001.